User's Manual

User Manual v1.0
UM - Everon 6000 DAS - 14-APR-2021 - clear of comments.docx| March 2021 |Page 144 of 202
Table 23: RIM RF Parameters Device Form Fields
Field
Information
DL Power Detector[dBm]
Power of base station down link transmission. Range is
-10 to +37[dBm].
Automatic Limit Control
(ON/OFF switch)
enable (On
= default)/disable (Off) ALC function for RIM
Service State
(ON/OFF switch)
Service State OFF simulates RIM is disconnected. Transmission disabled
by user.
Max Exp. Power [dBm]
User
defined max power for the base station transmission.
An alarm is triggered if the value in DL Power Detector field deviates from
this value.
UL Gain Mode
Auto Symmetrical
– equalizes the UL Gain
Manual (default)
– select a value in the range of -19 dB to
+15 dB (in 1dB
steps). Note that the enabled UL gain range is determined by the max
expected power setting.
UL Gain [dBm]
The configured maximum expected power determines the maximum UL
gain range enabled for configuration
Table 24: Max Expected Power Settings
Max Expected Power
Value [dBm]
Max UL Gain Range [dB]
0 -19 to +10
1 -19 to +11
2 -19 to +12
3 -19 to +13
4 -19 to +14
5 to 37 -19 to +15