User's Manual

User Manual v1.0
UM - Everon 6000 DAS - 14-APR-2021 - clear of comments.docx| March 2021 |Page 181 of 202
7.3 List of traps
The system supported traps (i.e., alert messages sent by the system to the SNMP manager, indicating system
events or failures), are provided in the following table.
Table 35: List of Traps
Trap name
Description
OID
controllerPowerUp
Controller power up indication
1
moduleDisconnected
Module disconnected
4
moduleDetected
Module detected
5
versionMismatchSet
Module Version Mismatch
6
versionMismatchClear
Module Version Mismatch clear
7
moduleAdjustmentFaultSet
Module Adjustment Fault
8
moduleAdjustmentFaultClear
Module Adjustment Fault clear
9
ModuleHwFailureSet
HW Failure
10
moduleHwFailureClear
HW Failure Clear
11
moduleInvalidChannelsMapSet
Module Invalid Channels Map set
12
moduleInvalidChannelsMapClear
Module Invalid Channels Map clear
13
adjustFaultSet
Adjustment Procedure Fault set
20
adjustFaultClear
Adjustment Procedure Fault clear
21
installFaultSet
Installation Fault set
22
installFaultClear
Installation Fault clear
23
releaseMismatchSet
SW Release Mismatch versions set
24
releaseMismatchClear
SW Release Mismatch versions clear
25
connectivitySet
Connectivity set
26
connectivityClear
Connectivity clear
27
hcmHeartbeat
HCM Heartbeat (Keep alive)
28
N/A
HCM HB Placeholder (not in use)
29
N/A
HCM License Placeholder (not in use)
30
N/A
HCM License Placeholder (not in use)
31
hcmInvalidChannelsMapSet
HCM Invalid Channels Map set
32
hcmInvalidChannelsMapClear
HCM Invalid Channels Map clear
33
hcmMissingEquipmentSet
HCM Missing equipment for the
Channels Map
34
hcmMissingEquipmentClear
HCM Missing equipment for the
Channels Map clear
35
acmPSMAOverTemperatureSet
ACM Power Supply A over Temperature
100
acmPSMAOverTemperatureClear
ACM Power Supply A over Temperature
Clear
101
acmOverTemperatureSet
ACM Over Temperature
102
acmOverTemperatureClear
ACM Over Temperature clear
103
acmPSMBOverTemperatureSet
ACM Power Supply B over Temperature
104
acmPSMBOverTemperatureClear
ACM Power Supply B over Temperature
Clear
105
acmPSMAOutputUnderVoltageSet
ACM Power Supply A Output Under
Voltage
108
acmPSMAOutputUnderVoltageClear
ACM Power Supply A Output Under
Voltage Clear
109
acmPSMBOutputUnderVoltageSet
ACM Power Supply B Output Under
Voltage
110
acmPSMBOutputUnderVoltageClear
ACM Power Supply B Output Under
Voltage Clear
111
acmExt1ClockDownSet
ACM Ext1 Clock down
114
acmExt1ClockDownClear
ACM Ext1 Clock down Clear
115
acmExt2ClockDownSet
ACM Ext2 Clock down
116