RF Connection
The RF interface between the Access Unit ( AU) and the service provider signal source (or Everon 6200CPOI) is provided
by duplex connections on the Active Combiner module. To route and connect the coaxial cables to the AU:
1. Obtain the required lengths of high performance, flexible, low-loss 50Ω coaxial cable for all coaxial connections and
route the cables from the signal source or CPOI to the Active Combiner module.
2. Connect the cables from the signal source to the QMA female connectors on the Active Combiner module on the
back panel of AU.
Note: Each Active Combiner module has four connectors to support up to four inputs.
AU Rear Panel Interfaces
SN Interface Name Description
1 Module 4 Duplexer Interface QMA Female
2 Module 3 Duplexer Interface QMA Female
3 Module 2 Duplexer Interface QMA Female
4 Module 1 Duplexer Interface QMA Female
5 Electric Power Line Interface /
6 Grounding /