User's Manual

Table Of Contents
Document : WCAMODHEL.sxw
0x07
RELAY_ROUTE : Table containing the radio
addresses for successive repeaters to use
to reach the final equipment.
BYTE 1 : number of repeaters in the
route
Maximum repeater number = 3
Si BYTE 1 != 0
BYTES 2 à 7 : First repeater radio
address
…, and so on.
1 à 19
0x08
POLLING_ROUTE : Table containing the list of
modules radio address to be addressed.
BYTE 2 : number of equipments to
interrogate
IF BYTE 2 != 0
BYTES 3 to 8 : radio address of the first
module..., and so on.
1 à
241
0x09
GROUP_NUMBER : Byte containing the
number of the group of radio equipment to
address in radio polling mode.
Group number
by default, GROUP_NUMBER = 0x00
1
0x0A
POLLING_TIME : delay between two
consecutive emission in polling mode
Value in multiples of 100ms
By default, POLLING_TIME = 0x0A
1
0x0C
RADIO_USER_TIMEOUT : time-out used for
the reception of a response frame
Value in multiples of 100ms
default value = 0x14 (2 seconds)
1
0x0E
EXCHANGE_STATU S : parameter relative to
the error or status frame management
activation.
0 : status and error frame deactivated,
1 : error frame activated,
2 : status frame activated,
3 : both status and error frames
activated,
by default, RECEPT_ERROR_STATUS =
0x00.
1
0x10
SWITCH_MODE_STATUS : automatic
selection of Radio physical mode used to
address an equipment depending on radio
address
0 : automatic selection deactivated
1 : automatic selection activated
Default value, SWITCH_MODE_STATUS
= 0x00
1
0x16
WAVECARD_MULTICAST_GROUP : Byte
containing the Multicast Group of the Wavecard
(available from V2.00 version ).
By default, no group selected = 0xFF 1
0x17
BCST_RECEPTION_TIMEOUT : timeout used for
the reception of CSMA frame consecutively to
REQ_SEND_BROADCAST Command emission
(available from firmware V2.01 version )
Valeur in multiples of100ms.
Default = 0x3C (6 seconds)
1
3.1.1 - Format of the internal parameters access
The Wavecard equipment manage internal parameters mainly relative to RF features. RS232 commands
allow to access these parameters in read or write mode. Default values are set at the first initialization of the
product.
REQ_READ_RADIO_PARAM command is used to read parameters and REQ_WRITE_RADIO_PARAM is
used to write parameters. Each parameter must be accessed individually.
CMD NOM DESCRIPTION
WCAMODHEL Handbook page 14 of 74