3.2.7 - Reading the RSSI level (Received Signal Strengh Indicator)
The RSSI level represent the QOS level (Quality Of Service) from a given module. This value can be used to
verify the quality of the signals forwarding on the network.
It is possible to take this measurement on a distant module, or the local module. The following examples
illustrate the types of measurements being able to be carried out.
Example 1 : Reading of RSSI, in Point-to-point mode.
REQ_READ_REMOTE_RSSI : request the RSSI level of the signal 1. (i.e. the RSSI level on signal 1
reception by the distant equipment)
REQ_READ_LOCAL_RSSI : request the RSSI level of the signal 2. (i.e. the RSSI level on signal 2
reception by the local equipment)
Example 2 : Request of reading of RSSI level on a distant module, in relaying mode.
REQ_READ_REMOTE_RSSI : request the RSSI level of the signal 1.
Therefore, to know the RSSI level between the repeaters, it will be necessary to make a request
REQ_READ_REMOTE_RSSI on each repeater.
a) Commands
CMD NAME DESCRIPTION
0x68 REQ_READ_REMOTE_RSSI request to read RSSI level from remote equipment.
0x69 RES_READ_REMOTE_RSSI Response to the read remote RSSI level request.
0x6A REQ_READ_LOCAL_RSSI
request to read the Wavecard RSSI level on an exchange with a
distant equipment.
0x6B RES_READ_LOCAL_RSSI Response to the read local RSSI level request.
Remark : In the command byte coding, the Response frame type are taking the Request command byte value
with the LSB bit set to 1.