User's Manual
Table Of Contents
- 1. INTRODUCTION
- 2. RS232 SERIAL PROTOCOL PRESENTATION
- 3. setting internal waveport CF parameters
- 3.1 Configuring functional parameters
- 3.2 Wake-up and synchronization
- 3.3 Configuring control parameters
- 3.3.1 Selecting RF communication mode
- 3.3.2 Selecting radio channel when FHSS is deselected
- 3.3.3 Selecting radio board transmission power
- 3.3.4 Activating RSSI threshold auto-correction
- 3.3.5 Selecting the serial baud rate
- 3.3.6 Reading Waveport CF firmware version
- 3.3.7 Reading RSSI
- 3.3.8 RSSI command format
- 3.3.9 TEST Mode
- 4. SERVICE COMMANDS
- 5. COMMUNICATION MODES
Waveport CF user manuel Coronis Systems
The format for data fields for reading or updating radio parameters is given below:
• Request to read radio parameters
REQ_READ_RADIO_PARAM
HEADER CMD DATA CRC ETX
3 bytes 1 byte 1 byte 2 bytes 1 byte
0xFF ; 0x02 ; 0x05 0x50 Number of the parameter to read 0x03
• Radio board response to parameter reading
RES_READ_RADIO_PARAM
HEADER CMD DATA CRC ETX
3 bytes 1 byte 1 byte variable 2 bytes 1 byte
0xFF ; 0x02 ; 0xXX 0x51
Status = 0x00 read ok
Status = 0x01 read error
value
-
0x03
• Request to update radio parameters
REQ_WRITE_RADIO_PARAM
HEADER CMD DATA CRC ETX
3 bytes 1 byte 1 byte variable 2 bytes 1 byte
0xFF ; 0x02 ; 0xXX 0x40
Number of the parameter
to update
Parameter data 0x03
• Radio board response to radio parameter update
RES_WRITE_RADIO_PARAM
HEADER CMD DATA CRC ETX
3 bytes 1 byte 1 byte 2 bytes 1 byte
0xFF ; 0x02 ; 0x05 0x41
STATUS
= 0x00 update OK
= 0x01 update error
0x03
Managing time-outs
Your product may need servicing if you consistently encounter the
following latencies. Please contact technical support for more
information.
REQ_WRITE_RADIO_PARAM 2 seconds
REQ_READ_RADIO_PARAM 2 seconds
Compact_Flash-UserManual 17