Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment • FAST SHIPPING AND DELIVERY • TENS OF THOUSANDS OF IN-STOCK ITEMS • EQUIPMENT DEMOS • HUNDREDS OF MANUFACTURERS SUPPORTED • LEASING/MONTHLY RENTALS • ITAR CERTIFIED SECURE ASSET SOLUTIONS SERVICE CENTER REPAIRS Experienced engineers and technicians on staff at our full-service, in-house repair center WE BUY USED EQUIPMENT Sell your excess, underutilized, and idle used equipment We also offer credit for buy-back
Basic Characteristics Data PBA/PBW Basic Characteristics Data Model Circuit method Switching frequency [kHz] Input current [A] PBA10F Flyback converter 100 0.3 PBA15F Flyback converter 100 0.4 PBA30F Flyback converter 100 0.7 PBA50F PBA75F Active filter 60 - 550 Forward converter 130 Active filter 60 - 550 Forward converter 120 0.7 Rated input fuse 250V 2.
AC-DC Power Supplies Enclosed type Instruction Manual PBA/PBW 1 Terminal Blocks PBA/PBW-34 2 Functions PBA/PBW-35 2.1 Input Voltage Range PBA/PBW-35 2.2 Inrush Current Limiting PBA/PBW-35 2.3 Overcurrent Protection PBA/PBW-36 2.4 Overvoltage Protection PBA/PBW-36 2.5 Thermal Protection PBA/PBW-36 2.6 Output Voltage Adjustment PBA/PBW-36 2.7 Remote ON/OFF PBA/PBW-37 2.8 Remote Sensing PBA/PBW-37 2.
AC-DC Power Supplies Enclosed type PBA/PBW 1 Terminal Blocks *The following information covers PBA300F - 1500F. Please see External View for PBA10F - 150F and PBW15F - 50F. ¿ PBA300F å 9 0 7 8 Instruction Manual 1AC (L) Input Terminals AC85 - 264V f47 - 63Hz 2AC (N) (M4) 3NC 4Frame ground (M4 ) 5-Output 6+Output 7LED 8Output voltage adjustable potentiometer 9CN1 0CN2 Connectors åCN3 *Please see Optional Parts for dedicated harnesses. H V. ADJ ¿ PBA1500T å 1 2 4 5 0 9 8 7 6 V.
AC-DC Power Supplies Enclosed type Pin Configuration and Functions of CN3 Pin No. Function 1 -S : -Sensing 2 -S : -Sensing 3 AUX : Auxiliary output (12V 0.1A) 4 RC1 : Remote ON/OFF 5 AUXG : Auxiliary output (GND) 6 N.C. : No connection 7 PG : Alarm 8 PGG : Alarm (GND) *Common signs among CN1, CN2 and CN3 such as -S represent the same potential.
AC-DC Power Supplies Enclosed type PBA/PBW ¿ PBA300F, PBA600F, PBA1000F, PBA1500F and PBA1500T ¡Thyristor technique is used in the inrush current limiting circuit. When you turn the power ON/OFF repeatedly within a short period of time, please have enough intervals so that the inrush current limiting circuit becomes operative.
AC-DC Power Supplies Enclosed type Please do not apply an external voltage of -0.7V or less or 3.0V or more. There is more than one method to adjust the output voltage, including the methods to use external resistors and external power supplies. Since each method has different characteristic, please contact us for details. ¡If the terminal TRM opens while the external output voltage control function is in use, a unit generates the rated voltage.
Instruction Manual AC-DC Power Supplies Enclosed type PBA/PBW Wire the se lines as close as possible ¿ PBA100F and PBA150F ¡Option -K is available (for -3R3 and -5) to support a remote sensing function. Please see ”7. Options” for details. CN1 ¿ PBA300F, PBA600F, PBA1000F, PBA1500F and PBA1500T R1 +V Load -V ¡These models have a built-in remote sensing function. If you do not use the remote sensing function, you can short out between +S and +M and between -S and -M on CN1.
AC-DC Power Supplies Enclosed type ¡The PG signal (Alarm) circuit is isolated from input, output, FG, RC and AUX. Instruction Manual 4.2 Parallel Operation/Master-slave Operation ¿ PBA10F, PBA15F, PBW15F, PBA30F, PBW30F, PBA50F, PBW50F, PBA75F, PBA100F and PBA150F 3 Peak Current ¡Parallel operation is not possible. ¡Redundancy operation is available by wiring as shown below.
AC-DC Power Supplies Enclosed type PBA/PBW Instruction Manual ¡You can adjust the output voltage in parallel operation by adjusting a potentiometer of just one power supply. ¡Hot-swap or Hot-plug is not available. ¡If 2 or more units failed, sufficient power could not be provided to To do so, select one power supply as the master unit and turn the the system. Therefore, please replace the failed unit immediately potentiometers of the other (slave) power supplies clockwise to the end.
Instruction Manual AC-DC Power Supplies Enclosed type 5.2 Derating Table 5.
AC-DC Power Supplies Enclosed type PBA/PBW Instruction Manual 5.3 Expected Life and Warranty ¡Warranty ¡Expected Life Please see the following tables for expected life.
Instruction Manual AC-DC Power Supplies Enclosed type ¡Please note the followings when measuring the voltage of the terminal CB. -Wire carefully to avoid malfunction caused by noise. -Use a measuring instrument whose input impedance is 500kW 7 Options 7.1 Outline of Options or more. -Do not short-circuit between CB terminal and -S terminal. Doing so could cause a failure. 6.
Instruction Manual AC-DC Power Supplies Enclosed type PBA/PBW ¿ -F4 (PBA300F, PBA600F, PBA1000F, PBA1500F and PBA1500T) -Option -F4 units have a low-speed low-noise fan instead of a standard fan. -Differences from standard versions are summarized in Fig.7.4. 100,000 10,000 30 40 50 60 70 80 Ambient temperature[C] Fig.7.1 Life expectancy of long-lived fan ¿ -F3 (PBA300F, PBA600F, PBA1000F, PBA1500F and PBA1500T) -Option -F3 units have a reverse air fan instead of a standard fan.
AC-DC Power Supplies Enclosed type ¿ -J (PBA10F, PBA15F, PBW15F, PBA30F, PBW30F, PBA50F, PBW50F, PBA75F, PBA100F and PBA150F) -Option -J units have Molex connectors instead of a terminal block. Instruction Manual R*1 RC (+) 1 RC (-) 2 Inside of a Power Supply Ri Input Current External Power Source -Dedicated harnesses are available for your purchase. Please see Optional Parts for details. SW Remote ON/OFF connector (Optional) Fig.7.
AC-DC Power Supplies Enclosed type PBA/PBW Instruction Manual Fig.7.8 Power supply installed on a DIN rail *External views are different among models. ¿ -V (PBA10F, PBA15F, PBW15F, PBA30F, PBW30F, PBA50F, PBW50F, PBA75F, PBA100F and PBA150F) -Option -V units have connector for external potentiometer instead of a built-in potentiometer. -Appearance of Option -V units is different from that of standard units. Please contact us for details.
Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment • FAST SHIPPING AND DELIVERY • TENS OF THOUSANDS OF IN-STOCK ITEMS • EQUIPMENT DEMOS • HUNDREDS OF MANUFACTURERS SUPPORTED • LEASING/MONTHLY RENTALS • ITAR CERTIFIED SECURE ASSET SOLUTIONS SERVICE CENTER REPAIRS Experienced engineers and technicians on staff at our full-service, in-house repair center WE BUY USED EQUIPMENT Sell your excess, underutilized, and idle used equipment We also offer credit for buy-back