Specifications
-
Dedicated harnesses are available for your purchase. Please
see Optional Parts for details.
*
1 If the output of an external power supply is within the range
of 4.5 - 12.5V, you do not need a current limiting resistor R. If
the output exceeds 12.5V, however, please connect the cur-
rent limiting resistor R.
To calculate a current limiting resistance value, please use the fol-
lowing equation.
R[
W
]=
*
Please wire carefully. If you wire wrongly, the internal components
of a unit may be damaged.
¡
Remote ON/OFF circuits (RC+ and RC-) are isolated from input,
output and FG.
¿
-N (PBA10F, PBA15F, PBW15F, PBA30F,
PBW30F, PBA50F, PBW50F, PBA75F,
PBA100F and PBA150F)
-
Option -N units come with a cover.
-
Appearance of Option -N units is different from that of standard
units. Please see External View for details.
-
Derating curve for Option -N units is different from that for stan-
dard units. Please see 5.2 Derating Curve for details.
-
UL508 is acquired (5V/ 12V/ 24V type in PBA10F/ PBA15F/
PBA30F with -N option, only 24V type in PBA50F/ PBA75F/
PBA100F/ PBA150F with -N option).
*
Safety agency approvals will be void if the cover is attached after
the unit is ex-factoried.
¿
-N1 (PBA10F, PBA15F, PBW15F, PBA30F,
PBW30F, PBA50F, PBW50F, PBA75F,
PBA100F and PBA150F)
-
Option -N1 units come with a dedicated DIN rail attachment.
-
Please contact us for details about appearance.
-
-Option -N1 units come with a cover (Option -N).
-
Each model has its own vibration and shock specifi cations.
¿
-J (PBA10F, PBA15F, PBW15F, PBA30F,
PBW30F, PBA50F, PBW50F, PBA75F,
PBA100F and PBA150F)
-
Option -J units have Molex connectors instead of a terminal
block.
-
Dedicated harnesses are available for your purchase. Please
see Optional Parts for details.
-
Please contact us for details about appearance.
-
For PBA100F and PBA150F, this option is available in -12, -15,
-24, -36 and -48 types.
-
Please do not apply more than 5A per 1 pin.
(1) Matching Molex Connectors and Terminals for PBA10F,
PBA15F, PBW15F, PBA30F, PBW30F, PBA50F and PBW50F.
(2) Matching Molex Connectors and Terminals for PBA75F,
PBA100F and PBA150F.
¿
-R (PBA50F, PBW50F, PBA75F, PBA100F
and PBA150F)
-
You can control output ON/OFF remotely in Option -R units. To
do so, connect an external DC power supply and apply a volt-
age to a remote ON/OFF connector, which is available as op-
tion.
AC-DC Power Supplies Enclosed type
Instruction Manual
PBA/PBW-45
PBA/PBW
Fig.7.7 Example of using a remote ON/OFF circuit
Vcc-(1.1+Ri
X
0.005)
0.005
CN1
CN2
AC(N)
AC(L)
NC
FG
-
+
Fig.7.6 Image of option -J (PBA50F)
I/O Connector Matching Housing Terminal
CN1 10-31-1048 10-63-3044
Reel : 08-70-1031
Loose : 08-70-1030
CN2 09-65-2049 09-50-1043
Reel : 08-70-1031
Loose : 08-70-1030
I/O Connector Matching Housing Terminal
CN1 10-31-1048 10-63-3044
Reel : 08-70-1031
Loose : 08-70-1030
CN2 09-65-2069 09-50-1063
Reel : 08-70-1031
Loose : 08-70-1030
Model Name
Built-in
Resistor
Ri [
W
]
Voltage between RC (+)
and RC (-) [V]
Input
Current
[mA]
Output ON Output OFF
PBA50F,
PBW50F,
PBA75F,
PBA100F
and
PBA150F
780 4.5 - 12.5 0 - 0.5 (20max)
Ri
RC
(-)
RC
(+)
2
1
*1
R
SW
External Power
Source
Remote ON/OFF connector (Optional)
Input Current
Inside of a Power
Supply
OG RDKPFF