STEP 3 - MAKE ELECTRICAL CONNECTION
After reading the requirements for each Electrical Connection method, follow
the instructions specific to your situation.
POWER CORD - U.S.A. ONLY
Disconnect power before servicing.
Use a new 50 amp UL listed or CSA certified power supply
cord. Plug into a grounded outlet.
Do not use an extension cord.
Failure to do so can result in death, fire, or electrical shock.
3-WIRE CONNECTION: POWER SUPPLY CORD
IMPORTANT: Use this method only if local codes permit connecting chassis
ground conductor to neutral wire of power supply cord.
1
. Disconnect power.
2. Remove the access panel located on the bottom right-hand side of the
back panel to uncover the electrical terminal block.
a
b
c
a Access Panel to Electrical
Supply Connection
b Power Cord Opening
c Recessed Area
Installation Instructions
13
3. Install a UL listed strain relief (not provided) to the power cord opening in
the bracket, and then completely tighten the strain relief nut.
4
. Thread the end of the power cord through the strain relief.
NOTE: Allow enough slack to connect the wires to the terminal
block.
c
a UL Listed Strain Relief
a
b Power Cord
b
c Jumper Wire
5
. Using a 5/16" nut driver and one of the -0-32 hex nuts, connect the neutral
(white) wire from the power cord to the center terminal block post along with
the green jumper wire from the range.
6. Using 10-32 hex nuts, connect the red and black wires from the power cord
to the outer posts of the terminal block with the corresponding red and
black wires from the range.
7. Tighten the hex nuts completely, and then verify the connection.
NOTE: For power supply cord replacement, use only a power cord rated
at 250volts minimum, 50-amps that is marked for use with nominal 1 3/8"
(3.5cm) diameter connection opening, with ring terminals and marked for
use with ranges.
8. Position the lower part of the strain relief under the power cord and tighten
the strain relief screws.
NOTE: Before tightening, make sure the strain relief is positioned over the
cord and NOT the wires.
9. Replace the electrical access panel.
10. Plug range into grounded outlet.
11. Tuck excess power cord into the recessed area of the back panel.