Full Product Manual
WARNING
20
STEP 4 - MAKE GAS CONNECTION
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure gas
pressure does not exceed 14" (36 cm) water column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion or fire.
TYPICAL FLEXIBLE CONNECTION
CONNECT BSPP TO NPT ADAPTER TO GAS REGULATOR:
1. Apply pipe-joint compound made for use with LP gas to the male threads of
adapter
c
.
2
.
Insert adapter
c
into outlet of the gas pressure regulator
d
, and then
tighten using two 10" adjustable wrenches. Be sure flow arrow on
regulator is pointing up toward the range gas inlet pipe.
3
.
Install washer
b
in female end of adapter
c
, and then connect adapter
c
to range gas inlet pipe
a
via compression fitting and tighten.
N
OTE: Washer
b
must be used to create a leak proof seal.
a
b
c
d
a Gas Line from Range
b Washer (provided)
c Adapter (provided)
d Gas Pressure Regulator
(provided)
Installation Instructions
21
CONNECT GAS LINE FROM GAS PRESSURE REGULATOR TO GAS SUPPLY:
1. Apply pipe-joint compound made for use with LP gas to the tapered (NPT)
threads of both adapters
d
supplied with gas line kit.
2
. Attach one adapter to the gas pressure regulator and the other to the
gas shutoff valve and tighten both.
N
OTE: Do Not rotate the gas pressure regulator.
3
.
Attach the flexible gas line
c
to adapters
d
, one adapter at each end.
IMPORTANT: All connections must be wrench tightened (requires two 10"
adjustable wrenches). Do not over-tighten the connections to the gas pressure
regulator. Overtightening may crack the regulator creating a leak.
b
c
e
a
d
d
a Adapter (provided)
b Gas Pressure Regulator
c Gas Supply Line
d Adapters (From Gas
Supply Line Kit)
e Gas Shutoff Valve
COMPLETE CONNECTION
1. Open the manual shutoff valve in the gas supply line. The valve is open when the
handle is parallel to the gas pipe.
2
. Test all connections by brushing on an approved noncorrosive leak-
detection solution. If bubbles appear, a leak is indicated. Correct any leak
found.
3
. Plug in range or reconnect power.
STEP 5 - INSTALL RANGE
IMPORTANT: If the range is moved to adjust the leveling legs, make sure
when you move the range back into its final location that the anti-tip bracket is
engaged by repeating steps 1 through 8.
1
. Slide range into final location, making sure rear leveling leg slides into anti-
tip bracket. Leave a 1" (2.5 cm) gap between the back of the range and the
back wall.
2
. Place the outside of your foot against the bottom front to keep the range
from moving, and then grasp the back of the range, as shown.
Installation Instructions
22 23