Full Product Manual

24
Burner and Orifice Characteristic Table
Burner Position
Orifice Gas Pressure Rate
Diam. (mm) Type [i.w.c.] [BTU/h]
Auxiliary Rear R 0.9 NG 4" 3500
0.58 LP (Propane) 10" 3500
Semi-Rapid Rear L and
Center
1.17 NG 4" 6000
0.75 LP (Propane) 10" 6000
Triple Front L 0.93 + 1.82 NG 4" 18000
1.14 + 0.56 LP (Propane) 10" 18000
Rapid Front R 1.6 NG 4" 11000
1.03 LP (Propane) 10" 11000
N
OTE: The triple burner has only two injectors, one injector mounted in the
center and one mounted below the cover plate. To access the second injector,
remove the two screws and the cover plate.
a
a Opening in grate for wok ring (provided) is located over left front burner.
T
ools Needed for Conversion:
Wrench
7 mm Nut Driver
Safety Glasses
Small Flat-head Screwdriver
Gas Conversion
25
STEP 1 - ADJUST THE GAS PRESSURE REGULATOR
IMPORTANT: Disconnect all electrical power, at the main circuit breaker or fuse
box. Shut off the gas supply to the range by closing the manual shut-off valve.
1
. Unscrew the regulator cap with the wrench.
a
a Regulator Cap
2
. Remove the retainer pin that is currently positioned for use with Natural Gas.
a
a Retainer Pin
3
. Turn the retainer pin upside down and replace it into the regulator cap. It is
now positioned for use with LP gas.
a
a Retainer Pin
4
. Screw the regulator cap back into the regulator.
Gas Conversion
26 27