Installation Guide
26
STEP 2 - CHANGE BURNER ORIFICES
IMPORTANT: Carefully read and observe each orifice label for correct location.
See the Burner Chart earlier in this section.
N
OTE: First remove all orifices and then start replacing them. This will help avoid
the possibility that some may not be replaced.
1
. Remove the burner grates, burner caps and burner heads.
2
. Using a 7mm nut driver, remove the burner orifices.
a
a
a Orifices
Triple Ring Burner
2 Orifices
Auxiliary Burner Semi-Rapid
Burner Rapid Burner
1 Orifice Each
3. Install the proper orifices in the exact locations as noted in the previous graphic.
Gas Conversion
4. Replace the burner bases, heads, caps and top grates. Make sure burner
caps are properly seated on the burner head.
27
Not Properly SeatedProperly Seated
STEP 3 - ADJUST BURNER
F
LAMES
NOTES:
•
Turn all burners on highest setting and check the flames. They should be
blue in color and may have some yellow tipping at the ends of the flame
when using LP gas. Foreign particles in the gas line may cause an orange
flame at first, but this will soon disappear.
•
Turn the cooktop burner knob to “LO” while observing the flame.
•
Adjustments must be made with two other burners in operation on a medium
setting. This prevents the upper row of flames from being set too low,
resulting in the flame being extinguished when other burners are turned on.
1
. Remove the knobs.
2
. Insert a screwdriver through the access hole in valve shaft as shown.
3
. Slowly turn the screw until the flame appearance is correct.
•
Open the valve more if the flames are too small or fluttered.
•
Close the valve more if the flames are too large.
Gas Conversion
STEP 4 - TESTING FLAME STABILITY
Test 1 - Turn the knob from “HI” to “LO” quickly. If the upper row of flames
goes out at this setting, increase the flame size and test again.
T
est 2 - With the burner on “LO”, open and close the cabinet door under
the cooktop. If the air currents created by the door moving extinguish
the flame, increase the flame height and test again.
STEP 5 - FLAME RE-CHECK
After the adjustment is made, turn all burners off. Ignite each burner individually.
Observe the flame at the “HI” position. Rotate the knob to the lowest setting and
be sure that the flame size decreases as the knob is rotated counterclockwise.
28 29