Installation Guide

Back of Range
a
b
c
a
Access Panel to Electrical
Supply Connection
b
Power Cord Opening
c
Recessed area
P
ower Supply
IMPORTANT: An electrical outlet in the floor, may be either recessed or surface
mounted, but an electrical outlet in the wall must be recessed to make the
connection. For Direct Wiring, the electrical box should be mounted to the wall.
a
b
e
d
g
h
c
f
a
30" (76 cm)
b
11½" (29.2 cm)
c
6" (15.2 cm)
d
7¼" (18.4 cm)
e
3" (7.6 cm)
f
17½" (44 cm)
g
Recommended Location for
Electrical Outlet
h
Recommended Location
for Gas Supply Connection
Installation Requirements
8
9
NOTE: 24" (61.0 cm) minimum clearance required when bottom of wood or metal
cabinet is covered by not less than ¹/" (0.64 cm) flame retardant millboard
covered with not less than No. 28 MSG sheet steel, 0.015" (0.4 mm) stainless
steel,
0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper. 30" (76.2 cm) minimum
clearance between the cooking and the bottom of an uncovered wood or metal
cabinet.
ELECTRICAL REQUIREMENTS
IMPORTANT: Use a 3-wire, UL listed, 30-amp minimum supply cord (pigtail);
or if local codes do not permit grounding through the neutral, use a 4-wire UL
listed, 30-amp minumum power supply cord rated at 250 volts and intended
for use with ranges.
If codes permit and a separate ground wire is used, it is recommended that
a qualified electrical installer determine that the ground path is adequate
and wire gauge is in accordance with local codes.
To properly install your range, you must determine the type of electrical
connection you will be using and follow the instructions provided for it here.
Range must be connected to the proper electrical voltage and frequency as
specified on the model/serial number rating plate. All models are dual rated,
and designed to be connected to either 120/240V or 120/208V AC, 60Hz,
single-phase, 3-wire or 4-wire, power supply.
Voltage and
Frequency
Amps Circuit Required
240V, 60 Hz 20A
25 Amp Circuit
208V, 60 Hz 17.4A
20 Amp Circuit
When a 4-wire, single-phase 120/240 volt, 60 Hz., AC only electrical
supply is available, a 25-amp maximum circuit protection is required (or, if
specified on the model/serial rating plate, when a 4-wire, single phase
120/208 volt 60 Hz., AC only electrical supply is available, a 20-amp
maximum circuit protection is required).
For direct wire installations, install a suitable conduit box (not furnished).
An appropriately sized, UL conduit connector must be used to correctly
attach the conduit to the junction box.
I
MPORTANT: Local Codes may vary; installation electrical connections
and grounding must comply with all applicable local codes.
If local codes permit grounding through the electrical supply neutral, connect
both the white neutral wire and the green ground wire from the oven to the
white neutral electrical supply wire.
ELECTRICAL REQUIREMENTS - U.S.A. ONLY
Do not use an extension cord.
Be sure that the electrical connection and wire size are adequate and in
conformance with the National Electrical Code, ANSI/ NFPA No. 70-latest
edition and all local codes and ordinances.
A copy of the above code standards can be obtained from:
National Fire Protection
Association One Batterymarch
Park
Quincy, MA 02269
Installation Requirements