Manifold pressure should be checked with a
manometer and comply with the values indicated
below:
Natural gas -> 4.0" W.c.P.
LP/Propane -> 10.0" W.C.P.
Incoming line pressure upstream from the
regulator must be 1" W.c.P. higher than the
manifold pressure in order to check the regulator.
The regulator used on this range can withstand a
maximum input pressure of 1/2 PSI (13.8" w.c. or
3,5 kPa) If the line pressure exceeds that amount,
a step-down regulator is required.
The appliance, its individual shut-off valve, and
the pressure regulator must be disconnected from
the gas line during any pressure testing of that
system at pressures in excess of 1/2 PSI (13.8"
w.c. or 3,5 kPa).
The individual manual shut-off valve must be in the
OFF position during any pressure testing of the
gas supply piping system at test pressures equal
to or less than 1/2 PSI (13.8" w.c. or 3,5 kPa).
 
Before carrying any service disconnect
the appliance from gas appliance from final install
have access to the appliance for proper servicing
intervention.
PRESSURE REGULATOR
Since service pressure may fluctuate with
local demand, every gas cooking appliance
must be equipped with a pressure regulator
on the incoming service line for safe and
efficient operation.
The pressure regulator shipped with the
appliance has two female threads 34" NPT.
The regulator shall be installed properly in
order to be accessible when the appliance
is installed in its final position.
GAS CONVERSION
WARNING!
Before carrying out this operation,
disconnect the appliance from gas
and electricity.
Gas conversion shall be conducted by a
factory- trained professional.
Call the customer service hotline to identify a
factory-trained professional near your home.
The gas conversion procedure for this range
includes 6 steps:
1. Pressure regulator
2. Surface burners
3. Adjustment of minimum setting
The conversion is not completed if all 6 steps
have not been concluded properly.
Before performing the gas conversion, locate
the package containing the replacement nozzle
shipped with every range. IMPORTANT: Each
nozzle has a number indicating its flow
diameter printed on the body. Consult the table
on page 20 for matching nozzles to burners.
Save the nozzles removed from the range for
future use.
1