Installation Guide

43
D
C
A
D
B
A. Rapid (Large)
B. Auxiliary (Small)
C. Triple Ring (X-Large)
D. Semi Rapid (Medium)
4. Replace the natural gas orifices with the correct LP gas orifices from the
LP conversion kits. LP gas orifices are stamped with a size. Refer to the
following chart for correct LP gas orifice ratings and sizes for proper
placement.
Orifice Chart for Surface Burners: F965 / F965NF
Burner Placement
LP Orifice
Size (mm)
NG Orifice
Size (mm)
Burner Rating
Rapid Front Left 0.91 1.45 9,500 BTU
Auxiliary Front Right 0.70 1.05 5,000 BTU
Triple Ring Center 1.22 2.10 18,000 BTU
Semi Rapid Rear Left 0.81 1.29 7,500 BTU
Semi Rapid Rear Right 0.81 1.29 7,500 BTU
5. Keep and store natural gas orifices in case of re-installation with natural
gas.
Orifice Size
(091 - Denotes 0.91 mm)
091