Installation Guide

INSTALLATION GUIDE
This appliance can be used with Natural Gas and LP Gas. It is shipped
from the factory adjusted for use with Natural Gas. Propane conversion
kits can be purchased separately.
The maximum inlet gas supply pressure incoming to the gas appliance
pressure regulator is 20’’ water column (5 kPa)
The minimum gas supply pressure for checking the regulator setting
shall be at least 1“ w.c. (249 Pa) above the inlet specified manifold
pressure to the appliance (this operating pressure is
4” w.c. (1.00 kPa) for Natural Gas and 10” w.c. (2.75 kPa) for LP Gas).
ATTENTION
A manual valve shall be installed in an accessible location in the gas
line external to the appliance for the purpose of turning on or shutting
off gas to the appliance
WARNING: Do not use aerosol sprays in the vicinity of this appliance
while it is in operation
INSERTING THE COOKTOP
After having removed the various loose parts from the internal and
external packing, make sure that the cooktop is not damaged and is
suitable for the specific gas usage. The gas type label is on the
underside of the cooktop base.
In case of doubt, do not use the appliance and contact skilled
personnel.
Keep all the packaging parts (polystyrene foam, cardboard, staples,
etc.) away from children.
Consider the critical dimensions of the appliance, before making an
opening in the top surface of the countertop. (relative measurements
as per Fig 1- 2).
5