User Manual
18 
Rigid pipe connection: 
The rigid pipe connection requires a combination of pipe fittings to obtain an 
in-line connection to the cooktop. The rigid pipe must be level with the 
cooktop connection. All strains must be removed from the supply and fuel 
lines so cooktop will be level and in line. 
Gas shutoff valve: 
A manual gas line shut-off valve must be installed in an easily accessible 
location. Do not block access to shut-off valve. The valve is for turning on or 
shutting off gas to the cooktop. 
GAS PRESSURE REGULATOR 
The gas pressure regulator supplied with this cooktop must be used. The inlet 
pressure to the regulator should be as follows for proper operation: 
TYPE OF GAS  MINIMUM PRESSURE  MAXIMUM PRESSURE 
Natural gas  4" WCP  14" WCP 
LP gas  10" WCP  14" WCP 
Contact local gas supplier if you are not sure about the inlet pressure. 
Burner Input Requirements 
Input ratings shown on the model/serial rating plate are for elevations up to 
2,000 ft (609.6 m). 
For elevations above 2,000 ft (609.6 m), ratings are reduced at a rate of 4% 
for each 1,000 ft (304.8 m) above sea level (not applicable for Canada). 
a b c
a
b
c
Gas supply line
Shutoff valve "open" position 
To cooktop