Full Product Manual

14
b) Any conversion required must be performed a qualified licensed gas service company. Please
provide the service person with this manual before work is started on the cooktops. (Gas conversions are
the responsibility of the dealer or end user.)
c) This cooktops can be used with NATURAL or LP/PROPANE gas. It is shipped from the factory
adjusted for use with LPG gas.
d) Manifold pressure should be checked with a manometer. NATURAL gas requires 5,0"W.C.P. and
LP/PROPANE requires 10,0" W.C.P. (see Figure 5.2-X).
Incoming line pressure upstream from the regulator must be 1" W.C.P. higher than the manifold
pressure in order to check the regulator.
The regulator used on this cooktops can withstand a maximum input pressure of 1/2 PSI
(14.0" W,C.P). If the line pressure is in excess of that amount. a step-down regulator will be required.
e) The appliance has individual shut-off valve, and pressure regulator must be disconnected
from the gas supply piping system during any pressure testing of that system at pressures in
excess of 1/2 PS (3.5 kPa).
3. Flexible Connections:
If local codes permit, CSA design-certified, flexible metal appliance connector is recommended for
connecting this cooktops to the gas supply line. Do not kink or damage the flexible connector when moving
the cooktops. The pressure regulator has 3/8" NPT female pipe threads. You will need to determine the
fittings required, depending on the size of your gas supply line, flexible metal connector and shutoff valve.
4. Rigid Pipe Connections:
If rigid pipe is used as a gas supply line, a combination of pipe fittings must be used to obtain an in-line
connection to the cooktops. All strains must be removed from the supply and fuel lines so cooktops will be
level and in line.
! Use joint compounds and gaskets that are resistant to action of natural or propane gas on all male
pipe threads.
! Do not over tighten gas fitting when attaching to pressure regulator. Over tightening may crack
regulator.
5. Leak Testing:
IMPORTANT: Leak testing of the appliance shall be conducted as follows:
! After final gas connection is made. turn on manual gas valve and test all connectors in gas supply
piping and appliance for gas leaks with a soapy water solution. During this test all appliance gas
valves have to be closed.
! In order to avoid property damage or serious personal injury, never use a lighted match. If a leak is
present tighten joint or unscrew apply more joint compound, tighten again and retest connection for
leak.