Owner`s manual

Warning - DO NOT use a pin or wire when
cleaning the burner orifice as damage can
occur to the precision opening. This can
cause damage to the refrigerator or create
a fire hazard. It will also create extremely
dangerous levels of carbon monoxide.
o The inlet & outlet gas fittings on the refrigerator need to be checked
for leaks. Apply a non corrosive bubble solution to the fittings and
observe for leaks. The safety valve will not allow gas pressure to any
connections between it and the burner orifice. These fittings must be
checked while burner is in operation (gas flow will be present between
safety valve and burner head)
WARNING The gas button D Fig#5 must
be manually depressed to allow gas pressure to
flow to the burner orifice. Be sure to apply the
leak check solution before depressing the safety
shut–off. DO NOT allow any open flame,
sparks, smoking, etc. in the area of the test. DO NOT depress safety
shut-off for over 30 seconds.
o If leak occurs, then allow ten minutes to dissipate from the burner
area. Fix leak then light the burner according to the instructions under
GENERAL OPERATING INSTRUCTIONS GAS OPERATION, CHAPTER 3