- Wind direction and/or velocity, including high
gusts of wind. Heavy air in the vent pipes
(cold/humid air with extended periods between
cycles).
- Negative pressure differential resulting from
the use of exhaust fans.
- Simultaneous operation of several fuel burning
appliances competing for limited air.
- Vent pipe connections vibrating loose from
clothes dryers, furnaces or water heaters.
- Obstructions in or unconventional vent pipe
designs which can amplify the above situations.
ALARM SIGNALS
Normal Operation – RED L.E.D. flashes once
every 30 seconds, indicating that the alarm is
powered.
Alarm Condition – RED L.E.D. turns “on” for
two seconds and “off” for three seconds with four
short beeps for one second and four seconds of
silence.
Fault Condition – RED L.E.D. double flash and
one beep every 30 seconds.
Low Battery – One beep every 30 seconds for a
minimum of seven days. Replace the battery when
the signal occurs.
MAINTENANCE
Cleaning your alarm:
To clean your alarm, remove it from the
mounting bracket. You can clean the interior of
your alarm by using your vacuum cleaner hose and
vacuuming through the openings around the
perimeter of the alarm.
The outside can be wiped with a clean towel.
Test your alarms weekly and repair or replace
them when they no longer function. As with any
electronic product, it has a limited life. Alarms that
do not work cannot protect you.
After cleaning, reinstall your alarm and test your
alarm by using the TEST button.
WARNING: Do not use any household cleaning
agents, paints, varnishes or any other chemical on
your 9RV alarm. Note: Regular testing is
recommended.
BATTERY REPLACEMENT
To replace the battery remove the alarm from the
mounting plate by rotating the alarm in the direction
of the “OFF” arrow on the cover.
The COSTAR Model 9RV CO Alarm uses one 9-
volt alkaline battery. A fresh battery should last for
one year under normal operating conditions.
USE ONLY THE FOLLOWING 9 VOLT
ALKALINE BATTERY FOR CO ALARM
REPLACEMENT. Alkaline type: DURACELL MN
1604.
WARNING: CHECK THE BATTERY
MANUFACTURERS SPECIFICATIONS FOR
PROPER OPERATING CONDITIONS.
NOTE: Most alkaline batteries are not rated
below –35 degrees C or above 52 degrees C.
WARNING: USE ONLY THE BATTERY
SPECIFIED. USE OF DIFFERENT BATTERIES
MAY HAVE A DETRIMENTAL EFFECT ON THE
CO ALARM.
THE CONSTANT EXPOSURE TO HIGH OR
LOW TEMPERATURS OR HIGH HUMIDITY MAY
REDUCE BATTERY LIFE.
PERIODIC ALARM TESTING
Test alarm weekly for proper operation by
pushing the test button until a short beep is heard
(approximately three seconds). Release the
button. The alarm will then test itself for proper
operation and the RED L.E.D. light will flash 4-5
times. At completion of the self-test, the alarm will
sound two patterns. The alarm then resumes
normal operation.
WARNING: TEST ALARM OPERATION AFTER
RV HAS BEEN IN STORAGE, BEFORE EACH
TRIP AND AT LEAST ONCE PER WEEK
DURING USE.
SERVICE AND WARRANTY
If you feel that your CO alarm is defective in any
way, do not tamper with the unit. Contact
Quantum Group’s customer service:
Quantum Group Inc.
11211 Sorrento Valley Road, Suite A
San Diego, CA 92121-1323
800/423-5599
mktsls@qginc.com