Product Specifications
MODEL
Output
DC Voltage Range
Programmable output Voltage (0% ~ 105%)
Programmable output Current (0% ~ 105%)
Power OK signal
Remote ON / OFF, Remote sense function
Protection: OVP, OLP, OTP, Fan failure
Rated Current
Current Range
Rated Power
Ripple & Noise (Max.)
Voltage Adj. Range
Voltage Tolerance
Line Regulation
Load Regulation
Setup, Rise Time
Hold Up Time (Typ.)
Input
Voltage Range
Frequency Range
Efficiency (Typ.)
AC Current (Typ.)
Inrush Current (Typ.)
Leakage Current
Protection
Over Load
Environment
Auxiliary Power
Power OK Signal
Output Voltage Trim
Working Temp.
Storage Temp. & Humidity
Working Humidity
Output Current Trim
Safety Standards
Withstand Voltage
Note.2
Note.3
Temp. Coefficient
Vibration
Power Factor (Typ.)
Over Temperature
±5.0% Typical adjustment by potentiometer. (VR1)
±2.0%
±1.0%
±1.0%
800ms, 100ms at full load
14ms / 230VAC at full load
90 ~ 264VAC, 127 ~ 370VDC
47 ~ 63Hz
30A / 115VAC, 60A / 230VAC
0.95 / 230VAC, 0.98 / 115VAC at full load
9.3A / 100VAC, 3.7A / 240VAC
89% 90%
92%
92%
92%
92%
105% rated output power, Protection type: Constant current limit
85 ±5°C detect on NTC, Protection type: Auto recovery after temperature goes down
Note.4
Selectable +5V / 0.5A or +9V / 0.3A auxiliary output
By external switch
Open drain signal low when PSU turns on, Max. sink current: 20mA, Max. drain voltage: 40V.
Adjustment of output voltage is between 0 ~ 105% of rated output
Adjustment of output current is between 0 ~ 105% of rated output
-20 ~ +60°C (Refer to de-rating curve)
20 ~ 90% RH non-condensing
-40 ~ +85°C, 10 ~ 95% RH
±0.02% / °C (0 ~ 50°C)
Load and temperature control fan
Over Voltage
Remote ON / OFF Control
Isolation Resistance
EMI Conduction & Radiation
Power Harmonic & Voltage
Fluctuation and Flicker
EMS Immunity
Cooling
Dimension (WxHxD)
Packing
Function
Others
Safety & EMC
Selectable +5V / 0.5A or +9V / 0.3A auxiliary output
AE-800-12
12V
66.7A
0 ~ 66.7A
800W
120mVp-p
AE-800-15 AE-800-24 AE-800-30 AE-800-36 AE-800-48 AE-800-60
15V
24V
30V 36V
48V 60V
53.4A 33.5A
26.7A
22.3A
16.7A
13.4A
0 ~ 53.4A 0 ~ 33.5A
0 ~ 26.7A
0 ~ 22.3A
0 ~ 16.7A
0 ~ 13.4A
800W 800W 800W 800W 800W 800W
150mVp-p 240mVp-p 300mVp-p 360mVp-p 480mVp-p 600mVp-p
Constant current limit
Remote setting multiple PSU via RS232, RS485 & I²C
< 1.0mA / 240VAC
10 ~ 500Hz, 2G 10min. / 1cycle, period for 60min. each along X, Y, Z axes Compliance to IEC 68-2-6, IEC 68-2-64
I/P-O/P: 3KVAC (4242VDC), I/P-FG: 1.5KVAC (2121VDC), O/P-FG: 0.5KVAC (707VDC)
I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC
Certified EN 55022; EN 61204-3; EN 61000-6-3
Certified EN 61000-3-2; EN 61000-3-3
Certified EN 55024; EN 61204-3; EN 61000-6-1; IEC 61000-4-2, 3, 4, 5, 6, 8, 11
Certified UL 60950-1; EN 60950-1
127x41x249 mm / 5.00x1.61x9.80 inch
1.7kg; 6pcs / 11.2kg / 0.55CUFT
93%
800W Programmable Single Output
AE-800 series
Note.6
Features:
Universal AC input / Full range
Note.7
Variable OVP, 120 ± 7% Vout. Refer to VCI VS OVP curve.
Protection type: Latch-style (Recovery after reset AC power ON or inhibit)
Parallel (Current Sharing)
Please refer to page 5
Note.5
Note
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uF & 47uF parallel capacitor.
3. Tolerance: includes setup time tolerance, line regulation and load regulation.
4. De-rating may apply in low input voltage. Please check the de-rating curve for more details.
5. In parallel connection only one unit will operate if the total output load is less than 5% of the rated power.
6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
7. This test is done without enclosure: I/P-O/P 4242VDC. If with enclosure: I/P-O/P 2121VDC,I/P-FG:2121VDC, O/P-FG: 707VDC
REV. D0
16/12/20
1
Forced current sharing at parallel operation
Global control via RS232
Address Setting
Up to 8 units can be set using an address switch (sw1), 0~7
MTBF
112K HRS Certified MIL-HDBK-217F