AE & AEK Series Communication Protocol

8-2-5
Power ON / OFF / Query
Syntax: POWER <type>
Parameter: 0 <= type <= 2
Description:
<type> = 0: To Power off SMPS. Control mode will change to REMOTE
<type> = 1: To Power on SMPS. Control mode will change to REMOTE
<type> = 2: Query the status of power ON/OFF,
Echo : 0 -> Remote Disable, Power Off.
1
-> Remote Disable, Power On.
2
-> Remote Enable,
3 -> Remote Enable,
8-2-6
Output Voltage Setting
Syntax: SV <value>
Power Off.
Power On.
Parameter: value -> Voltage value for setting.
Description: Output Voltage Setting.
e. g. To set output voltage to 11.95V, the command is: SV 11.95 CR LF
8-2-7
Output Current Setting
Syntax: SI <value>
Parameter: value -> Current value for setting.
Description: Output Current Setting
e. g. To set output current to 105.5A, the command is: SI 105.5 CR LF
8-2-8 Voltage setting Query
Syntax: SV?
Parameter: None.
Description: Query the output voltage setting. SMPS will respond the voltage setting value
8-2-9
Current setting Query
Syntax: SI?
Parameter: None.
Description: Query the output current setting. SMPS will respond the current setting value.
8-2-10
Output Voltage Query
Syntax: RV?
Parameter: None.
Description: To query the output voltage value