Product Specifications
MODEL
Output
DC Voltage Range
Rated Current
Current Range
Rated Power
Ripple & Noise (Max.)
Voltage Adj. Range
Voltage Tolerance
Line Regulation
Load Regulation
Setup, Rise Time
Hold Up Time (Typ.)
Input
Voltage Range
Frequency Range
Efficiency (Typ.)
AC Current (Typ.)
Inrush Current (Typ.)
Leakage Current
Protection
Environment
Auxiliary Power
Power OK Signal
Output Voltage Trim
Working Temp.
Storage Temp. & Humidity
Working Humidity
Output Current Trim
Note.2
Note.3
Temp. Coefficient
Vibration
Power Factor (Typ.)
Over Temperature
±5.0% Typical adjustment by potentiometer. (VR1)
±2.0%
±1.0%
±1.0%
800ms, 50ms at full load
14ms / 230VAC at full load
90 ~ 264VAC, 127 ~ 370VDC (Refer to de-rating curve)
47 ~ 63Hz
33A / 115VAC, 65A / 230VAC
0.95 / 230VAC, 0.98 / 115VAC at full load
19.7A / 115VAC (2000W), 14.5A / 230VAC (3000W)
Note.4
Selectable +5V / 0.5A or +9V / 0.3A auxiliary output
By external switch
Open drain signal low when PSU turns on, Max. sink current: 20mA, Max. drain voltage: 40V.
Adjustment of output voltage is between 0 ~ 105% of rated output
Adjustment of output current is between 0 ~ 105% of rated output
-20 ~ +60°C (Refer to de-rating curve)
20 ~ 90% RH non-condensing
-40 ~ +85°C, 10 ~ 95% RH
±0.02% / °C (0 ~ 50°C)
Load and temperature control fan
Remote ON / OFF Control
Cooling
Dimension (WxHxD)
Packing
Function
Others
AEK-3000-200
150V
15A
3000W
< 1.0mA / 240VAC
10 ~ 500Hz, 5G 10min. / 1cycle, period for 60min. each along X, Y, Z axes Compliance to IEC 60068-2-6, IEC 60068-2-64
170x64x280 mm / 6.69x2.52x11.02 inch
3.8kg; 4pcs / 16.2kg / 2.48CUFT
REV. B6
17/07/26
1
250V
10A
AEK-3000-250
93%
1500mVp-p
0 ~ 15A
0 ~ 12A
105% rated output power
Over Voltage
AEK-3000 series
3000W Programmable Single Output
Over Load
Protection type: Constant current limit
Programmable output Voltage (0% ~ 105%)
Programmable output Current (0% ~ 105%)
Power OK signal
Remote ON / OFF function
Protection: OVP, OLP, OTP, SCP, Fan failure
Selectable +5V / 0.5A or +9V / 0.3A auxiliary output
Constant current limit
Remote setting multiple via RS232, RS485 & I²C
Features:
High power density 16.3W / inch³
Universal AC input / Full range
Forced current sharing at parallel operation
Note
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uF & 47uF parallel capacitor.
3. Tolerance: includes setup time tolerance, line regulation and load regulation.
4. De-rating may apply in low input voltage. Please check the de-rating curve for more details.
5. In parallel connection only one unit will operate if the total output load is less than 5% of the rated power.
6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
7. This test is done without enclosure: I/P-O/P 4242VDC. If with enclosure: I/P-O/P 2121VDC,I/P-FG:2121VDC, O/P-FG: 707VDC
Parallel (Current Sharing)
Please refer to page 5
Note.5
Protection type: Latch-style (Recovery after reset AC power ON or inhibit)
Global control via RS232
400V
7.5A
AEK-3000-400
0 ~ 7.5A
Variable OVP, 120 ± 7% Vout. . Refer to VCI VS OVP curve
AEK-3000-150 AEK-3000-300
300V
200V
20A
12A
0 ~ 20A 0 ~ 10A
85 5± °C detect on NTC, Protection type: Auto recovery after temperature goes down
2000mVp-p 2500mVp-p 3000mVp-p 4000mVp-p