AEK-3000 LV Datasheet

MODEL
Output
DC Voltage Rated
Rated Current
Current Range
Rated Power
Ripple & Noise (Max.)
Voltage Adj. Range
Voltage Tolerance
Line Regulation
Load Regulation
Setup, Rise Time
Hold Up Time (Typ.)
Input
Voltage Range
Frequency Range
Efficiency (Max.)
AC Current (Max.)
Inrush Current (Typ.)
Leakage Current
Protection
Environment
Auxiliary Power
Power OK Signal
Output Voltage Trim
Working Temp.
Storage Temp. & Humidity
Working Humidity
Output Current Trim
Safety Standards
Withstand Voltage
Note.2
Note.3
Temp. Coefficient
Vibration
Power Factor (Typ.)
Over Temperature
±5.0% Typical adjustment by potentiometer. Via V-Adj from PSU front panel)(
±2.0% (rated output voltage of single unit)
±1.0%
±1.0%
800ms, 100ms at full load
14ms / 230VAC at full load
90 ~ 264VAC , 127 ~ 370VDC (Refer to de-rating curve)
47 ~ 63Hz
33A / 115VAC, 65A / 230VAC
0.95 / 230VAC, 0.98 / 115VAC at full load
19.7A / 115VAC (2000W), 16.5A / 230VAC (3000W)
Note.4
Selectable +5V / 0.5A or +9V / 0.3A auxiliary output
By external switch
Open drain signal low when PSU turns on, Max. sink current: 20mA, Max. drain voltage: 40V.
Adjustment of output voltage is between 0 ~ 105% of rated output
Adjustment of output current is between 0 ~ 105% of rated output
-20 ~ +60°C (Refer to de-rating curve)
20 ~ 90% RH non-condensing
-40 ~ +85°C, 10 ~ 95% RH
±0.02% / °C (0 ~ 50°C)
90.6K HRS Certified MIL-HDBK-217F
Remote ON / OFF Control
Isolation Resistance
EMI Conduction & Radiation
EMS Immunity
MTBF
Dimension (WxHxD)
Packing
Function
Others
AEK-3000-12
12V
200A
2400W
150mVp-p
AEK-3000-15 AEK-3000-24
AEK-3000-30 AEK-3000-36
15V
24V
30V 36V
48V
60V
160A 125A 100A
83.5A
62.5A 50A
2400W
3000W 3000W 3006W 3000W 3000W
< 3.5mA (240VAC)
10 ~ 500Hz, 2G 10min. / 1cycle, period for 60min. each along X, Y, Z axes Compliance to IEC 60068-2-6, IEC 60068-2-64
I/P-O/P: 3KVAC (4242VDC), I/P-FG: 1.5KVAC (2121VDC), O/P-FG: 0.5KVAC (707VDC)
I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC (25 /70%ΡΗ)°C
Certified EN 55032
Certified EN 61000-3-2; EN 61000-3-3
Certified EN 55024; IEC 61000-4-2,3,4,5,6,8,11
Certified UL 62368-1; EN 62368-1
170x64x280 mm / 6.69x2.52x11.02 inch
3.9kg; 6pcs / 25.9kg / 2.48CUFT
88% 89% 91% 91% 92% 92% 93%
0~200A 0~160A 0~125A 0 ~ 100A
0 ~ 83.5A
0 ~ 62.5A 0 ~ 50A
AEK-3000-48
AEK-3000-60
Over Load
105% rated output power
Over Voltage
AEK-3000 series
Safety & EMC
Note.6
3000W Programmable Single Output
Protection type: Constant current limit
Note.7
Parallel (Current Sharing)
Please refer to page 5
Note.5
Note
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uF & 47uF parallel capacitor.
3. Tolerance: includes setup time tolerance, line regulation and load regulation.
4. De-rating may apply in low input voltage. Please check the de-rating curve for more details.
5. In parallel connection only one unit will operate if the total output load is less than 5% of the rated power.
6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
7. This test is done without enclosure: I/P-O/P 4242VDC. If with enclosure: I/P-O/P 2121VDC,I/P-FG:2121VDC, O/P-FG: 707VDC
Variable OVP Refer to VCI VS OVP curve.(OVP Tolerance ±7%)
Protection type: Latch-style (Recovery after reset AC power ON or inhibit)
Programmable output Voltage (0% ~ 105%)
Programmable output Current (0% ~ 105%)
Power OK signal
Remote ON / OFF, Remote sense function
Protection: OVP, OLP, OTP, SCP, Fan failure
Selectable +5V / 0.5A or +9V / 0.3A auxiliary output
Constant current limit
Remote setting m via RS232, RS485 & ultiple PSU I²C
Features:
Built-in active PFC Function
Universal AC input / Full range
Forced current sharing at parallel operation
(Refer to pg. 5 for connection diagram)
Global control via RS232
Power Harmonic & Voltage
Fluctuation and Flicker
85 5± °C detect on NTC, Protection type: Auto recovery after temperature goes down
150mVp-p 240mVp-p 300mVp-p 360mVp-p 480mVp-p 600mVp-p
Current Tolerance
±3.0% (rated output current of single unit)
REV. C2
22/02/16
1
2022/02/16
C2
Carlos
CB
IEC62368-1
Load and temperature control fan
Cooling