Data Sheet

MODEL
Output
DC Voltage Range
Programmable output Voltage (30% ~ 105%)
Programmable output Current (40% ~ 105%)
+5V / 0.5A auxiliary output
Power OK signal
Remote ON / OFF, Remote sense function
Protection: OVP, OLP, OTP, SCP, Fan failure
Rated Current
Current Range
Rated Power
Ripple & Noise (Max.)
Voltage Adj. Range
Voltage Tolerance
Line Regulation
Load Regulation
Setup, Rise Time
Hold Up Time (Typ.)
Input
Voltage Range
Frequency Range
Efficiency (Typ.)
AC Current (Typ.)
Inrush Current (Typ.)
Leakage Current
Protection
Over Load
Environment
Auxiliary Power
Power OK Signal
Output Voltage Trim
Working Temp.
Parallel (Current Sharing)
Storage Temp. & Humidity
Working Humidity
Output Current Trim
Safety Standards
Withstand Voltage
Note.2
Note.3
Temp. Coefficient
Vibration
Power Factor (Typ.)
Forced current sharing at parallel operation
Over Temperature
AK-650-05
5V
AK-650-12 AK-650-15 AK-650-24 AK-650-27
AK-650-48
12V 24V
15V
27V
48V
100A 50A 40A
27A 24A
13.6A
0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A
0 ~ 13.6A
500W 600W 600W 650W 650W 650W
150mVp-p 150mVp-p <1%(mVp-p), according to the rated output voltage
±5.0% Typical adjustment by potentiometer
±1.0%
±0.5%
±0.5%
800ms, 60ms at full load
16ms / 230VAC at full load
90 ~ 264VAC, 127 ~ 370VDC
47 ~ 63Hz
27A / 115VAC, 54A / 230VAC
0.98 / 230VAC, 0.99 / 115VAC at full load
7.5A / 115VAC, 3.5A / 230VAC
< 1.0mA / 240VAC
83% 88% 90%88% 90% 91%
105 ~ 125% rated output power
Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)
By detecting primary and secondary heat sink.
Protection type: Shut down o/p voltage (Recovers automatically after temperature goes down)
Note.4
5V / 0.5A (±3%)
External switch or NPN Transistor to turn ON / OFF
Open drain signal low when PSU turns on, Max. sink current: 20mA, Max. drain voltage: 40V.
Adjustment of output voltage is between 30 ~ 105% of rated output
Adjustment of output current is between 40 ~ 105% of rated output
Please refer to Function Manual
-25 ~ +60°C (Refer to de-rating curve)
20 ~ 90% RH non-condensing
-40 ~ +85°C, 10 ~ 95% RH
±0.02% / °C (0 ~ 50°C)
10 ~ 500Hz, 5G 10min. / 1cycle, period for 60min. each along X, Y, Z axes Compliance to IEC 68-2-6, IEC 68-2-64
I/P-O/P: 3KVAC (4242VDC), I/P-FG: 1.5KVAC (2121VDC), O/P-FG: 0.5KVAC (707VDC)
I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC
Certified EN 55022; EN 61000-6-3, -6-4
Certified EN 61000-3-2; EN 61000-3-3
Certified EN 55024; EN 61204-3; EN 61000-6-1; ENV 50204; IEC 61000-4-2, 3, 4, 5, 6, 8, 11
Load and Temperature control fan
127x41x249 mm / 5.00x1.61x9.80 inch
1.68kg; 9pcs / 16.1kg / 1.86CUFT
Remote ON / OFF Control
Isolation Resistance
EMI Conduction & Radiation
Power Harmonic & Voltage
Fluctuation and Flicker
EMS Immunity
Cooling
Dimension (WxHxD)
Packing
Function
Others
Note.5
166.2K HRS Certified MIL-HDBK-217FMTBF
Protection type: Latch-style (Recovery after reset AC power ON or inhibit)
Note
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uF & 47uF parallel capacitor.
3. Tolerance: includes setup time tolerance, line regulation and load regulation.
4. De-rating may apply in low input voltage. Please check the de-rating curve for more details.
5. In parallel connection, only one unit will operate if the total output load is less than 5% of the rated load condition.
6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still
meets EMC directives.
7. This test is done without enclosure: I/P-O/P 4242VDC. If with enclosure: I/P-O/P 2121VDC,I/P-FG:2121VDC, O/P-FG: 707VDC
Certified UL 60950-1; EN 60950-1
650W Single Output Power Supply
AK-650 series
Safety & EMC
Note.6
Over Voltage
Variable OVP, 125 ±10% Vout.
REV. E6
16/12/20
1
Note.7
Universal AC input / Full range
Features:

Summary of content (6 pages)