Installation Guide

1
User Guide For CR-16 Remote Control
1. Features
z Battery bank voltage display
z Output power display
z Error condition indicator High Battery, Low Battery, Over Temperature, Over Load conditions
z Action condition indicator INV, GRID, POWER SAVING, CHARGING STATUS
z Connection failure notification
2. Specification
z Input Voltage : 10.5 ~ 66 Vdc
z Operating Temperature Range : 0 ~ 40
z Storage Temperature Range : - 30 ~70
z Stand-By Current Draw : < 80mA
z Applicable Models : SP series – 700 / 1000 / 1500 / 2000 / 3000 / 4000
SL series – 2000 / 3000
* Note
Grid LED is only functional when connecting SP series with TR-40.
3. Introduction
3-1. Front Panel Introduction
Fig.1 Front Panel Introduction
M Power ON/OFF Button P Battery voltage indicator
N Charging Status LED Q Other Indicators
O Output power indicator
M Power ON/OFF Button
Power ON/OFF button is to turn the inverter on or off.
N Charging Status LED (BULK / ABSORPTION / FLOAT) shows the charging status: (Only applicable to
SL series)
x BULK: When the battery is in low voltage status, the battery is charged at constant current by
maximum charge current.
x ABSORPTION: When the battery is near fully charged, the battery keeps charging by constant
voltage mode.
x FLOAT: When the battery is fully charged, this state maintains the battery at 100% charge without
overcharging or damaging the battery.
Please refer to the detail information in SL series user manual accordingly.