CR-16A User Guide

1
User Guide For CR-16 Remote Control
1. Features
Battery bank voltage display
Output power display
Error condition indicator High Battery, Low Battery, Over Temperature, Over Load conditions
Action condition indicator INV, GRID, POWER SAVING, CHARGING STATUS
Connection failure notification
2. Specification
Input Voltage : 10.5 ~ 66 Vdc
Operating Temperature Range : 0 ~ 40
Storage Temperature Range : - 30 ~ 70
Stand-By Current Draw : < 80mA
Applicable Models : SP series – 700 / 1000 / 1500 / 2000 / 3000 / 4000
SL series2000 / 3000
* Note
Grid LED is only functional when connecting SP series with TR-40.
3. Introduction
3-1. Front Panel Introduction
Fig.1 Front PanelIntroduction
Power ON/OFF Button Battery voltage indicator
Charging Status LED Other Indicators
Output power indicator
Power ON/OFF Button
Power ON/OFF button is to turn the inverter on or off.
Charging Status LED (BULK / ABSORPTION / FLOAT) shows the charging status: (Only applicable to
SL series)
BULK: When the battery is in low voltage status, the battery is charged at constant current by
maximum charge current.
ABSORPTION: When the battery is near fully charged, the battery keeps charging by constant
voltage mode.
FLOAT: When the battery is fully charged, this state maintains the battery at 100% charge without
overcharging or damaging the battery.
Please refer to the detail information in SL series user manual accordingly.
Output power indicator
Output power indicator shows the power draw from the power inverter by the load. Ideally, the output
power indicator should remain in the green & orange area of the bar chart.
If the output power indicator is up to the red area, the OLP LED will flash and the inverter will shut down.
REMOTE CONTROL CR-16A
OVP
INV
PWR.
SAV.
GRID
UVP OLP OTP
20
40
60
80
100
Low
Norm.
High
BATTERY
VOLTAGE POWER (%)
OUTPUT
REMOTE CONTROL CR-16B
FLOAT
ABSORPTION
BULK
OVP
INV
PWR.
SAV.
GRID
UVP OLP OTP
CHG
20
40
60
80
100
Low
Norm.
High
BATTERY
VOLTAGE POWER (%)
OUTPUT
33
55
2
11
44

Summary of content (3 pages)