Product Specifications

MODEL
Output
Battery Type
CX1215
CX1225 CX1235 CX1250
CX1280
Input
Protection
Over Voltage
Environment
Working Temp.
Working Humidity
Storage Temp., Humidity
Temp. Coefficient
Vibration
-20 ~ 50°C (refer to output load de-rating curve)
20 ~ 90% RH non-condensing
-40 ~ +85 , 20 ~ 90% RH°C
±0.03% (0 ~ 50°C)
10 ~ 500Hz, 2G 10min. / 1cycle period for 60min. each along X, Y, Z axes
Safety & EMC
EMI Conduction & Radiation
Isolation Resistance
EMS Immunity
Harmonic Current
Withstand Voltage
I/P-O/P: 4242VDC, I/P-FG: 1768VDC, O/P-FG: 700VDC
I/P-O/P: 100M Ohms / 500VDC
Others
Packing
1.6kg 1.7kg 1.9kg 3.1kg 4.0kg
Dimension (WxHxD)
183x72x mm243 183x72x243mm 183x72x263mm 213x77x272mm 213x77x312mm
Note
Certified EN 55022; EN 61204-3; EN 55014-1
Certified EN 55024; IEC 61000-4-2, 3, 4, 5, 6, 8, 11; ENV 50204; EN 61000-6-1; EN 55014-2
Certified EN 61000-3-2, -3-3; EN 61204-3; EN 61000-6-3
Lead Acid / Gel / AGMLi-ion /
Standard Boost Charge Voltage
Standard Float Charge Voltage
14.4V / 14.7V (Select by S1-1)
13.8V / 13.5V (Select by S1-2)
Main Rated Current
Current Range
Main Output
Battery Charging Mode
15A 25A 35A 50A 80A
0 ~ 15A 0 ~ 25A
0 ~ 35A
0 ~ 50A 0 ~ 80A
12
23
3
3 - stage charging capability (IUOU)
Voltage Range
Power Factor (Typ.)
Frequency Range
AC Current (Typ.)
Leakage Current
Efficiency (Typ.) at 230VAC
90 ~ 264VAC
PF > 0.92 at full load
47 ~ 63Hz
87% 87% 87%
87%
87%
2.5 A / 100VAC
1.07A / 240VAC
4.1 A / 100VAC
1.8A / 240VAC
6.2 A / 100VAC
2.8A / 240VAC
8.24 A / 100VAC
3.6A / 240VAC
13.3 A / 100VAC
5.4A / 240VAC
For earth < 1mA / 240VAC
Short Circuit
Over Temperature
Current is reduced to < 1A continued 30sec. , fan will operate 30 seconds then turn off
17.5V 1%,± Protection type: Shut down output (recovery after resetting AC power on)
Charger 100 ±5°C detected by heat sinkOver Temperature
Battery Over Temperature 52 ±5°C (Optional device - COTEK temperature sensor), connect on CN3
Function
Alarm Signal
NC. / NO. Relay contact output ( )Please refer to page 5 Alarms Signal & Fan Control
Temperature Compensation
Charging Sleep Mode
By and S1-4 DIP switch ( )Remote Controller Please refer to page 4~5
-10mV / 0.5°C with COTEK temperature sensor
1. All parameters not specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. The charger is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC
directives.
3. Before charging, make sure the battery charger and battery specifications compatible.
4. When use sleep mode, refer to charging
5.
°C
are
please current v.s. heat sink temperature de-rating curve.
Optional Remote Controller (CR-1).
Single Output Current Limit
15A 25A 35A 40A 40A
Note.4
Remote Controller
Support COTEK Remote Controller CR-1 setting Function (CN3 or CN4)
ESB Output
11
1
ESB Output Voltage / Current
13.8V / 2A 13.8V / 2A
1
13.8V / 2A
——
——
Safety Standards
Certified EN 60335-1, EN 60335-2-29
Note.2
Protection type: Auto recovery after heat sink temperature goes down to 50°C
Advanced Battery Charger
CX12xx
Compatible with Lead Acid, Li-ion, Gel and AGM batteries
Universal AC input with active PFC
Voltage / temperature compensation with battery temp. sensor (Optional)
Dry contact for alarm
2-stage fan speed control
High efficiency and high reliability
Protection: Short Circuit / Over Voltage / Over Temperature / Brown-out
Built-in battery rescue function
Built-in Engine Start Battery (ESB) output function
Features:
Withstand 2G vibration test
Support optional remote controller (CR-1)
Note.5
Power Mode
Supply 13.2V Current limit output voltage
RS-232 communication interface
Output power OK signal
REV. A7