CX12xx Datasheet

MODEL
Output
Battery Type
CX1215
CX1225 CX1235 CX1250
CX1280
Input
Protection
Over Voltage
Environment
Working Temp.
Working Humidity
Storage Temp., Humidity
Temp. Coefficient
Vibration
-20 ~ 60°C (refer to de-rating curve)
20 ~ 90% RH non-condensing
-40 ~ +85 , 20 ~ 90% RH°C
±0.03% (0 ~ 50°C)
10 ~ 500Hz, 2G 10min. / 1cycle period for 60min. each along X, Y, Z axes
Safety & EMC
Isolation Resistance
EMC Standards
Withstand Voltage
I/P-O/P: 4242VDC, I/P-FG: 1768VDC, O/P-FG: 700VDC
I/P-O/P: 100M Ohms / 500VDC
Others
Packing
1.6kg 1.7kg 1.9kg 3.1kg 4.0kg
Dimension (WxHxD)
183x72x mm243 183x72x243mm 183x72x263mm 213x77x272mm 213x77x312mm
Note
Certified EN 61204-3; EN 55014-1
Certified IEC 61000-4-2, 3, 4, 5, 6, 8, 11; EN 61000-6-1; EN 55014-2
Certified EN 61000-3-2, -3-3; EN 61000-6-3
Lead Acid / Li-ion / Gel / AGM
Standard Boost Charge Voltage
Standard Float Charge Voltage
14.4V / 14.7V (Select by S1-1)
13.8V / 13.5V (Select by S1-2)
Main Rated Current
Current Range
Main Output
Battery Charging Mode
15A 25A 35A 50A 80A
0 ~ 15A 0 ~ 25A
0 ~ 35A
0 ~ 50A 0 ~ 80A
1 2
2 3
3
3 - stage charging capability (IUOU)
Voltage Range
Power Factor (Typ.)
Frequency Range
AC Current (Typ.)
Leakage Current
Efficiency (Typ.) at 230VAC
90 ~ 264VAC (refer to de-rating curve)
PF > 0.92 at full load
47 ~ 63Hz
87% 87% 87%
87%
87%
2.5 A / 100VAC
1.07A / 240VAC
4.1 A / 100VAC
1.8A / 240VAC
6.2 A / 100VAC
2.8A / 240VAC
8.24 A / 100VAC
3.6A / 240VAC
13.3 A / 100VAC
5.4A / 240VAC
For earth < 1mA / 240VAC
Short Circuit
Over Temperature
Current is reduced to < 1A continued 30sec. , fan will operate 30 seconds then turn off
17.5V ± 1%, Protection type: Shut down output (recovery after resetting AC power on)
Charger 100 ±5°C detected by heat sinkOver Temperature
Battery Over Temperature 52 ±5°C (Optional device - COTEK temperature sensor), connect on CN3
Function
Alarm Signal
NC. / NO. Relay contact output ( )Please refer to page 5 Alarms Signal & Fan Control
Temperature Compensation
Charging Sleep Mode
By and S1-4 DIP switch ( )Remote Controller Please refer to page 4~5
-10mV / 0.5°C with COTEK temperature sensor
1. All parameters not specially mentioned are measured at 230VAC input, rated load and 25
of ambient temperature.
2. The charger is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC
directives.
3. Before charging, make sure the battery charger and battery specifications are compatible.
4. When using sleep mode, please refer to charging current vs. Ambient temperature de-rating curve.
5.
°C
Optional Remote Controller (CR-1).
Single Output Current Limit
15A 25A 35A 40A 40A
Note.4
Remote Controller
Support COTEK Remote Controller CR-1 setting Function (CN3 or CN4)
ESB Output
1 1
1
ESB Output Voltage / Current
13.8V / 2A 13.8V / 2A
1
13.8V / 2A
Safety Standards
Ul458 (only for CX1235/1250/1280) , Certified EN 60335-1, EN 60335-2-29
Note.2
Protection type: Auto recovery after heat sink temperature goes down to 50°C
Advanced Battery Charger
CX12xx
Compatible with Lead Acid, Li-ion, Gel and AGM batteries
Universal AC input with active PFC
Voltage / temperature compensation with battery temp. sensor (Optional)
Dry contact for alarm
2-stage fan speed control
High efficiency and high reliability
Protection: Short Circuit / Over Voltage / Over Temperature / Brown-out
Built-in battery rescue function
Built-in Engine Start Battery (ESB) output function
Features:
Withstand 2G vibration test
Support optional remote controller (CR-1)
Note.5
Power Mode
Supply 13.2V Current limit output voltage
RS-232 communication interface
Output power OK signal
REV. B3
20/10/20
1

Summary of content (7 pages)