CX2440 User Guide

6
EN
2-2. Specification
Model CX1215 CX1225 CX1235 CX1250 CX1280
Output
Battery Type
Lead Acid / Li-ion / Gel / AGM
Standard Boost Charge
Voltage
14.4V / 14.7V (Select by S1 DIP switch)
Standard Float Charge
Voltage
13.8V / 13.5V (Select by S1 DIP switch)
Main Rated Current 15A 25A 35A 50A 80A
Main Output 1 2 2 3 3
ESB Output 1 1 1 -- --
ESB Output Voltage /
Current
13.8V/2A 13.8V/2A 13.8V/2A -- --
Battery Charging Mode 3-stage charging capability IUOU
Isolation Type Use active power MOSFET on each output terminal
Single Output Current Limit 15A 25A 35A 40A 40A
Input
Nominal Voltage
100~240VAC (100~120VAC only for UL458)
Voltage Range 90~264VAC (90-132VAC only for UL458) (Refer to 2-2-2 de-rating curve)
Frequency Range 47~63Hz
Power Factor (Typ.) PF > 0.92 at full load
Efficiency (Typ.) at 230Vac 87% 87% 87% 87% 87%
Protection
Short Circuit
Current is reduced to < 1A continued 30sec.,
will operate 30 seconds then turn off
Over Voltage
17.5V ±1%, protection type: shut down output
(recovery after resetting AC power ON)
Over Temperature
Charger Over Temperature 100 ±5°C detected by heat sink
52±5°C (Optional temperature sensor)
Auto recovery after heat sink temperature goes down to 50±5°C
Function
Alarm Signal
NC. / NO. Relay contact output (Please reference Alarms signal & Fan control)
Temp. Compensation
12V-10mv / 0.5°C with COTEK temperature sensor
24V-20mv / 0.5°C with COTEK temperature sensor
Sleep Mode By Remote Controller and S1-4 DIP switch (Please refer to section 3-2)
Remote Controller Support COTEK Remote Controller CR-1 (Refer to section 3-6 and 3-7)
Environment
Working Temperature
-20~40°C (Refer to 2-2-2 de-rating curve)
Working Humidity 20~90% RH non-condensing
Temperature Coefficient ±0.03% (0~50°C)
Vibration 10~500Hz, 2G 10min. / 1cycle period for 60min. each along X, Y, Z axes.
Safety
&
EMC
Safety Standards
Certified EN 60335-1, EN 60335-2-29, UL458 (only for CX1235/1250/1280)
Withstand Voltage I/P-O/P: 4242VDC, I/P-FG: 1768VDC, O/P-FG: 707VDC
Isolation Resistance I/P-O/P: 100M Ohms / 500VDC
EMC Standards
Certified EN 55022; EN 61204-3; EN 55014-1
Certified EN 61000-3-2; EN 61000-3-3; EN 61204-3; EN 61000-6-3
Certified EN 55024; IEC 61000-4-2, 3, 4, 5, 6, 8, 11; ENV 50204; EN
61000-6-1; EN 55014-2
Others
Dimension
(WxHxD) 183x72x243 mm 183x72x263 mm 213x77x272 mm 213x77x312 mm
Packing 1.6 kg 1.7 kg 1.9 kg 3.1 kg 4.0 kg