Datasheet

MODEL
Output
DC Voltage Range
10W Miniature Single Output Power Supply
DN-10
Features :
Universal AC input 88 - 264Vac
Protections: Short circuit / Over load / Over voltage
Brown-out protection
All using 105°C long life electrolytic capacitors
series
True DC OK signal output
High operation temperature up to 70°C
Withstand 2G vibration test
High efficiency, long life and high reliability
3 years warranty
DN-10-24DN-10-12 DN-10-15
Rated Current
Current Range
Rated Power
Ripple & Noise (max.)
Voltage Adj. Range
Voltage Tolerance
Line Regulation
Load Regulation
Setup, Rise Time
Hold Up Time (Typ.)
12V
0.84A
0 ~ 0.84A
10.08W
100 mVp-p
10.8 ~ 13.2V
±1%
±1%
±1%
<800ms, <100ms/230Vac at full load
> ms / 230VAC >16ms / 115VAC at full load32
15V
0.67A
0 ~ 0.67A
10.05W
100 mVp-p
±1%
±1%
Input
Voltage Range
Frequency Range
Efficiency (Typ.)
AC Current (Typ.)
Inrush Current (Typ.)
Leakage Current
88V ~ 264VAC 124 ~ 370VDC
47Hz ~ 63Hz
81% 81%81%
0.23 A / 115VAC 0.17A / 230VAC
15A / 115VAC 30A / 230VAC
<1mA / 230VAC
Protection
Over Load
Over Voltage
> 102 % rated output power
Protection type : constant current limiting, automatically after fault condition is removed
115% ~ 150% rated output voltage
Protection type : latch-off mode
Envi onmentr
Working Temp.
Working Humidity
Storage Temp., Humidity
Temp.Coefficient
Vibration
-20°C ~ 70°C (Refer to output load de-rating curve)
20 ~ 90% RH non-condensing
-40 ~ +85°C, 10 ~95% R.H
±0.03%/°C (0 ~ 50°C)
10 ~ 500Hz, 2G 10min./1 cycle, period for 60 min. Each along X,Y,Z axes
Safety & EMC
Safety Standards
EMI Conduction & Radiation
Isolation Resistance
EMS Immunity
Harmonic Current
Withstand Voltage
UL508, TUV EN60950-1 : 2006+A11, UL1310 NEC class 2 compliant
I/P - O/P:3KVAC (4242 DC) I/P - FG:1.5KVAC (2121 DC) 1 minute
I/P - O/P, I/P - FG, O/P - FG: 100M Ohms / 500VDC
Others
Cooling
Packing
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47 uf parallel
capacitor.
3. Tolerance: includes set up tolerance, line regulation and load regulation.
4. De-rating may be needed under low input voltages. Please check the de-rating curve for more details.
5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be
re-confirmed that it still meets EMC directives
0.13kg ; 48Pcs / 7.44kg
Note
Installed on DIN rail TS35 / 7.5 or 15
UL508 ( Industrial control equipment ) listed
UL1310 Class 2 Power unit / LPS pass
Note.2
Note.3
Note.4
DC OK signal
Open collector. Max : 40mA
Connection
I/P 3 poles, O/P : 3 poles screw DIN terminal
Dimension (W*H*D)(mm)
23x90x99
Free Air convection
13.5 ~ 16.5V
±1%
24V
0.42A
0 ~ 0.42A
10.08W
120 mVp-p
±1%
±1%
21.6 ~ 26.4V
±1%
Note.5
MTBF (MIL-HDBK-217F)
562.7K HRS
EN55022 : 2006+A1:2007 Class B
EN61204-3: 2000, EN55024: 1998+A1: 2001+A2: 2003 light industry level, criteria A
EN61000-3-2:2006 Class A, EN61000-3-3:2008
REV. B2
10/10/19
1