SC Series User Manual

11
EN
Table 4
SC series front panel introduction
3-2-1. DIP(Function) switch(reference E)
3-2-1-1 Output Voltage switch Function (S1,S2)
Output Voltage
S1
S2
100V / 200V
OFF
OFF
110V / 220V
ON
OFF
115V / 230V
OFF
ON
120V / 240V
ON
ON
Table 5
Output voltage function definition
3-2-1-2 Output Frequency switch Function (S3)
Frequency
S3
50HZ
OFF
60HZ
ON
Table 6
Output frequency function definition
3-2-1-3 AC Input Current Limit Select (S4,S5,S6)Default : 15A/10A
AC Input Current
100~120V / 200~240V
S4
S5
S6
3A / 2A
OFF
OFF
OFF
6A / 4A
ON
OFF
OFF
9A / 6A
OFF
ON
OFF
12A / 8A
ON
ON
OFF
15A / 10A
OFF
OFF
ON
20A / 12A
ON
OFF
ON
25A / 14A
OFF
ON
ON
30A / 16A
ON
ON
ON
Table 7
SC series Input current limit select function definition
3-2-1-4 Battery Type Select Function(S7,S8)Default : GEL
Table 8
Battery types select function definition
Battery Type
S7
S8
GEL
OFF
OFF
Flooded
ON
OFF
AGM
OFF
ON
Customer
ON
ON