SC Series User Manual

28
EN
ITEM
RANGE
Default
SHORE POW. MAX
110V system: 3A~30A
220V system: 2A~16A
110V system: 15A
220V system: 10A
01 Search Watts
110V system: OFF, 1W~20W
220V system: OFF, 1W~40W
110V system: 20W
220V system: 20W
02 Batt Under Voltage Protect
12V system: 10.00V~11.50V
24V system: 20.00V~23.00V
12V system: 10.5V
24V system: 21.0V
03 Batt Over Voltage Protect
12V system: 15.00V~16.50V
24V system: 30.00V~33.00V
12V system: 16.5V
24V system: 33.0V
04 Grid Under Voltage Protect
110V system: 90.0V~110.0V
220V system: 180.0V~220.0V
110V system: 90V
220V system: 180V
05 Grid Over Voltage Protect
110V system: 125.0V~132.0V
220V system: 250.0V~264.0V
110V system: 132V
220V system: 264V
06 Bulk Charge Time
0.5HR~20.0HR
8.0Hr
07 Battery Type
GEL,FLOOD,
AGM1,CUSTOM
GEL
08 Charge Rate
25%~100%
100%
09 Abs Charge Time
0.5HR~10.0HR
8.0Hr
10 Equalization
ACTIVE, INACTIVE
INACTIVE
11 UPS Mode
DISABLE,
ENABLE (0-30MIN)
DISABLE
12 Generator Mode
DISABLE, ENABLE
ENABLE
13 NIGHT Mode
DISABLE, ENABLE
DISABLE
14 Auto ESB
DISABLE, ENABLE
DISABLE