Product Specifications
The Battery Charger
Safety and EMS
Other
SC-1200-112 SC-1200-124 SC-1200-212 SC-1200-224
1200W Pure Sine Wave Inverter / Charger SC-1200 series
BULK ABSORPTION FINAL
BATTERY VOLTAGE
CURRENT (I)
T
Imax
<Imax
Start max builk timer: 13.50 VDC
13.50VDC
14.40VDC
Reurn to bulk : 12.80VDC
BULK
ABSORPTION FLOAT
BULK
repeated
every 336 hr
85
mm
30
sec
return to
bulk timer
Bulk
Float
lmax 100%
Return amps= 6% lmax
= voltage
= current
12.80VDC
Charge characteristic of the three-step Plus charging method
min. bulk timer : 2 min
Absorption
14.25VDC
max. bulk
timer : user
select
8 ~ 18 hr
max. absorption
timer: 4 hr
min. abs timer : 15 min
Three step charge system
Charge characteristic of three-step plus charging method
Safety Standards
E-mark
EMC Standards
Dimension (W x H x D)
Net Weight
UL458 & Supplement SA / UL1741
---
Certified FCC Class A*
251 x 116 x 386mm
4.55Kg
EN 62368-1
Certified CISPR 25; ISO7637-2
EN55032 Class A*, EN55024 Class A*
EN61000-3-2, 3-3 , EN61000-4-2, 3, 4, 5, 6, 8, 11
*Max Inverter output define inverter 100% load output at Vac =100V / 200V
*Max AC output define AC input current + Inverter output current, cannot over AC input limit.
*Max AC input current Limit by the Breaker
*For SC-1200 -112 and -124, the operating temperature range certified by UL Safety Standard is -20°C ~ 40°C.
*SC series is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.