Product Manual

2
1-3. Installation
The power inverter should be installed in a location that meets the following
requirements
Dry Do not allow water to drip or splash on the inverter.
Cool Ambient air temperature should be between -20 and 50, but he cooler
the better.
Safety Do not install batteries in the compartment or other areas here flammable
fumes existence such as fuel storage areas or engine compartments.
Ventilated Allow at least one feet of clearance around the Inverter for air flow.
Ensure the ventilation shafts on the rear and bottom of the unit are not
obstructed.
Dust-free Do not install the Inverter in dusty environments here dust, wood
particles or other filings/shavings are present. The dust can be pulled
into the unit when the cooling fan is in operation.
Close to batteries Avoid excessive cable lengths but do not install the inverter in
the same compartment as batteries.
Use the recommended wire lengths and sizes (refer to section 4.DC wiring
connections).
Do not mount the inverter where it is exposed to the gases produced by the battery.
These gases are very corrosive and prolonged exposure will damage the inverter.
WARNING!
Shock Hazard. Before proceeding further, carefully check that the inverter is
NOT connected to any batteries, and that all wiring is disconnected from any
electrical sources . Do not connect the output terminals of the inverter to an
incoming AC source.