Specifications Sheet

3500W Pure Sine Wave
SD3500 series
3500W
(
)
de-rating after 35°C, refer to de-rating curve for 12V)
(de-rating after 40°C, refer to de-rating curve for 24V and 48V
SD3500-212 SD3500-224 SD3500-248SD3500-112 SD3500-124 SD3500-148
91%91%90%91%90%
40.0~64.0VDC
48VDC
@48VDC
20.0~32.0VDC
24VDC
@24VDC
12VDC
10.0~16.0VDC
@12VDC
48VDC24VDC
40.0~64.0VDC
20.0~32.0VDC
10.0~16.0VDC
@48VDC
@24VDC
Pure Sine Wave
100 / 110 / 115 / 120VAC ±3% 200 / 220 / 230 / 240VAC 3%±
50 / 60Hz ±0.1%
Parallel redundancy design for power expansion
Automatic master mechanism to eliminate single point
failure and optimize reliability
Built-in ATS and AC circuit breaker
RS-232 communication
Input & output fully isolation
Output voltage / power saving mode selectable by DIP switch or
remote control (CR-10)
Input Protection: Reverse Polarity (Fuse) / Under Voltage / Over Voltage
Output Protection: Short Circuit / Overload / Over Temperature /
Over Voltage
Features:
Optional STS module, transfer time less 4ms.
0.5A
0.5A
1.4A
0.5A
0.5A
1.4A
Multiple industrial applications that create 1 3W / 3 4W power systems Ф Ф
20Ax620Ax12 20Ax620Ax1240Ax12
47 - 57 / 53 - 63 Hz
20A
Optional STS module : Single < 4ms; N+1&1P3W&3P4W < 6ms
Standard ATS : Inverter to utility AC:8~10ms.; Utility AC to inverter: 16~50ms.
Load & Thermal control fan
283x128x496 mm / 11.14x5.04x19.53 inch
RS-232 (RJ-11 type connector), Ethernet (optional)
Max. 90%, non-condersing
-40 ~ +70°C
Reverse Polarity (Fuse) / Under Voltage / Over Voltage Protection / AC over current (Breaker)
Short Circuit / Overload / Over Temperature / Over Voltage
50.0VDC
62.0VDC
64.0VDC
25.0VDC
31.0VDC
32.0VDC
30.0VDC
12.5VDC
15.5VDC
16.0VDC
15.0VDC
50.0VDC
62.0VDC
64.0VDC
60.0VDC
25.0VDC
31.0VDC
32.0VDC
30.0VDC
40.0VDC20.0VDC10.0VDC40.0VDC20.0VDC
42.0VDC10.5VDC42.0VDC21.0VDC
-20 ~ +60°C; refer to SD3500 power de-rating curve
Input voltage level, faulty status
CR-6, CR-8 and CR-10
Certified EN60950-1
** UL 458 (UL only for hardwire)Certified
21.0VDC
60.0VDC
Rating Power
Efficiency (Max.)
DC Voltage
Voltage Range
No load Power Consumption
Waveform
Output Frequency
Output Voltage (@rated VDC)
Peak Power (3Sec.)
Surge Power (<0.2Sec.)
On Mode @ No Load Mode
On Mode @ Save Mode
AC Range
Frequency Selectable
Synchronous Frequency
Circuit Breaker
Transfer Switch ***
Cooling
Parking
Dimension (WxHxD)
Communication Port
Relative Humidity
Working Temp.
Storage Temp.
BAT.High Alarm ±3%
BAT.High Restart ±3%
BAT.Low Restart ±3%
BAT.High Shut-down ±3%
Input Protection
Output Protection
BAT.Low Shut-down ±3%
BAT.Low Alarm ±3%
LED Indicator
Remote control
Safety Standards
Output
DC Input
Fuse
Others
Environment
Protection
Control & Signal
Safety & EMC
AC Input
MODEL
4500W
6000W
90%
12VDC
@12VDC
40Ax12
50 / 60 Hz
35A
12.5VDC
15.5VDC
16.0VDC
15.0VDC
10.0VDC
10.5VDC
10 kg; 2pcs / 21kg / 3.19cuft
< 3% @ under condition : greater than 1.15 times
of the rated VDC, 110V / linear load)
Total Harmonic Distortion (THD)
< 3% @ under condition : greater than 1.15 times
of the rated VDC, 230V / linear load)
Certified FCC Class B
EMC Standards
Note
*UL-458 only support 112 and 124 model.
**EN55014-1, EN55014-2 Class B : output cable less than 2 meters.
***Please refer to Transfer - Time Table.
Certified CISPR 25; ISO 7637-2
E-Mark
REV. A5
16/06/29
1
< 2.9A < 1.4A < 0.8A < 3.6A < 1A< 1.8A
100 / 110 / 115 / 120VAC 25%, recover± ±12.5% 200 / 220 / 230 / 240VAC 25%± , recover±12.5%
**Certified EN 55014-1,
EN 61000-3-2, 3-3, EN61204-3;
EN 55014-2,
EN 61000-6-1, -6-2, -6-3, -6-4
IEC 61000-4-2, 3, 4,5, 6, 11