Product Specifications

2000W Inverter / Charger
SL-2000 series
REV. A0
16/12/02
1
The unit is equipped with a self diagnosis microprocessor
that is able to identify and show all failure messages on
the LED/LCD display, with associated visual/audio alarms
Features:
Can use parallel with the grid AC
Battery charger current 100A max. @12VDC
Equalization function for the batteries.
Built in 50A rated bypass switch.
Power sharing functions.
Intelligent software for power management
Hard-wire connection model option.
Loading and temperature controlled cooling fan
Local and remote management and control
RS-232 communication
By a dry contact terminal
Advanced protection features :
DC input over/under voltage protection
Internal over temperature, battery over temperature and heat sink over temperature
Inverter AC output overload protection
Inverter AC output short circuit protection
AC input short circuit protection: Breaker (50Amp)
AC input under / over voltage protection
Electical
SL-2000-112
12 VDC
9 ~ 10.5 VDC
Nominal Voltage
Input Over-Voltage Protection
Stand-By Power Consumption
Input Voltage Range
Max. DC input current
Input Under-Voltage Protection
No Load Power Consumption
Absolute Max. DC Input
LBCO/LBCI (Low Battery Cut Out/In)
Inverter Mode
16.5 ~ 17 VDC
17 VDC±0.3V
9 ~ 17 VDC±0.3V
25W
<5W
25 VDC
9 VDC±0.3V
HBCO/HBCI (High Battery Cut Out/In)
267ADC
<16 msec
AC Relay Transfer Time
Surge Power (real watts)
Frequency
60 Hz ± 0.1
5 sec : 3400 (Tentative)
Continuous Output Power
2000 VA
Short-Circuit Protection
Output Waveform
Pure Sine Wave (THD < 5%)
Yes
Output Voltage
Max. Efficiency
>90%
120 VAC ±5% (Continuous Power)
30 sec : 3200 (Tentative)
5 min : 2900 (Tentative)
30 min : 2300 (Tentative)
Specification Item
Input
Output
Charger Mode
Charger
Equalization
Battery Temperature Compensation
25 mV per °C
80 ~ 140 VAC±5% (120VAC nominal)
5 ~ 50A*
AC Input Voltage Range
AC Input Frequency Range
AC Input Current Range
Charger Efficiency (Peak)
AC Nominal Current
50 ~ 70 Hz
85%
15A
Power Factor Correction(PFC)
>0.97 (50% Load)
Battery Temperature Protection
Charging Current Range
Four-stage charging
By a RJ-11 connector to battery temperature sensor
0 ~ 100A
Bulk, Absorb, Float, Equalize*
16VDC
Max. Output Voltage
Max. Output Current
10A
Bypass Switch
AC 50 Amp
Switch Specification
(Max. each input)
Note
*Setting by remote control