Installation Manual

26
Note! Fault conditions include Input under / over voltage,
output short circuit / over load, over / under temperature.
Caution! Please follow the following steps for the
installation
z Before installing the inverter, make sure the main switch is at
“OFF” position.
z Before using the remote function, make sure the main switch
pressed toward “REMOTE”
z Use 20 ~ 24 #AWG wire to connect the remote control terminals
Figure 16. Wiring for control
3-2-3. General instruction before DC Input
3-2-3-1 Before installation:
The DC cables should be as short as possible (less than 6 feet /
1.8 meters ideally)
The size of the cable should be thick enough to limit the voltage
drop to less than 2% when carrying the maximum input current
to prevent frequent low-input voltage warnings, and shutdown.
The following sizes of cables and fuses are recommended
distance (<6 ft.) between the batteries and the inverter.