Installation Manual

32
Function Command and description
Query the SP series output
current
Format: IINV?
Query the SP series status
Format: ERR? (SP-700~2000)
Bit Description
BIT0
0: No OLPL Protection
1: OLPL Protection
BIT1
0:No Sof Fail Protection
1:SofFail Protection
BIT2
0:No Poff Protection
1:Poff Protection
BIT3
0:No UVP Protection
1:UVP Protection
BIT4
0:No OVP Protection
1:OVP Protection
BIT5
0:No OLPM Protection
1: OLPM Protection
BIT6
0:No OLPH Protection
1: OLPH Protection
BIT7
0:No OTP Protection
1: OTP Protection
BIT8
0:No UTP Protection
1: UTP Protection
BIT9
0:No OOCP Protection
1: OOCP Protection
* Status definition refer to Table 35. Status definition
Format: ERR? (SP-3000~4000)
Bit Description
BIT0
0: No ID Fail
1: ID Fail
BIT1
0:No Sof Fail Protection
1:SofFail Protection
BIT2
0:No PLL Fail
1:PLL Fail
BIT3
0:No Poff Protection
1:Poff Protection
BIT4
0:No Short Protection
1:Short Protection
BIT5
0:No OOCP Protection
1: OOCP Protection
BIT6
0:NoOVP Protection
1:OVP Protection
BIT7
0:No UVP Protection
1:UVP Protection