SP-Series Quick Start Guide

Quick Product Introduction
SP series
SP Series
Scan QR Code to view
the User Manual
Pure Sine Wave Inverter
Please download and read the user manual from COTEK website or QR code before starting to use the SP Inverter.
IMPORTANT: Please must read the Installation and Maintenance Instructions Before Connecting to the Supply.
2020.10_A1
Output
SP-700 SP-1000 SP-1500 SP-2000 SP-3000 SP-4000
Protection
Control & Signal
Control & Signal
Environment
Output
SP Series - 112 SP Series - 124 SP Series - 148 SP Series - 212 SP Series - 224 SP Series - 248
Input
Safety & EMC
Protection
100 / 110 / 115 / 120 VAC (Dip Switch Selectable)
± 5%
Pure Sine Wave ( THD<5% @ Normal Load )
Rated Power
Surge Power ( Max. 1 Sec )
Surge Power ( Max. 3 Sec )
Maximum Output Power (1 Min)
Frequency
Output Overload & Short
Input Protection
Over Temperature
DC input Reverse Polarity
Shutdown output voltage, restart to recovery
Over / Under Voltage, Reverse Polarity (Internal Fuse)
Heat sink temperature over 80
o
C ± 5
o
C, shutdown output voltage, recover automatically after heat sink temperature goes down to 60
o
C ± 5
o
C
By Fuse
Accessory (Optional)
LED Indicator
Dry Contact Terminal
Remote Control
Remote ControlCR-8 / CR-16A; Transfer SwitchTR-40
Input voltage level, output load level and faulty status
By relay
6-port green terminal Terminal
Dimension (WxHxD)
Packing
Cooling
Application
200x83x330 mm /
7.87x3.27x12.99 inch
2.6kg; 6pcs / 16.6kg /
3.59 CUFT
Temperature & load controlled cooling fan
Home and oce appliances, portable power equipment, vehicle, yacht and o-grid solar power
200x83x372 mm /
7.87x3.27x14.65 inch
3.26kg; 4pcs / 14kg /
2.65 CUFT
248x83x421 mm /
9.76x3.27x16.57 inch
4.42kg; 4pcs / 22.68kg /
3.54 CUFT
248x83x443 mm /
9.76x3.27x17.44 inch
5.24kg; 4pcs / 21.96kg /
3.58 CUFT
255x158x442 mm /
10.04x6.22x17.40 inch
8.2kg; 2pcs / 17.4kg /
3.05 CUFT
255x158x462 mm /
10.04x6.22x18.19 inch
10kg; 2pcs / 21kg /
3.05 CUFT
Working Temp.
Storage Temp.
Storage Temp. & Humidity
-20
o
C ~ 40
o
C, ( -40W/
o
C, 41~60
o
C )
-30
o
C ~ 70
o
C
10 ~ 95 % RH non-condensing
700 VA
>1050VA ~ 1400VA
(151% ~ 200%)
>810VA ~ 1050VA
(116% ~ 150%)
>700VA ~ 810VA
(100% ~ 115%)
50 / 60 Hz ± 0.5% (Dip Switch Selectable)
1000 VA
>1500VA ~ 2000VA
(151% ~ 200%)
>1150VA ~ 1500VA
(116% ~ 150%)
>1000VA ~ 1150VA
(100% ~ 115%)
1500 VA
>2250VA ~ 3000VA
(151% ~ 200%)
>1725VA ~ 2250VA
(116% ~ 150%)
>1500VA ~ 1730VA
(100% ~ 115%)
2000 VA
>3000VA ~ 4000VA
(151% ~ 200%)
>2300VA ~ 3000VA
(116% ~ 150%)
>2000VA ~ 2300VA
(100% ~ 115%)
3000 VA
>3450VA ~ 6000VA
(116% ~ 200%)
>3000VA ~ 3450VA
(100% ~ 115%)
4000 VA
>4600VA ~ 8000VA
(116% ~ 200%)
>4000VA ~ 4600VA
(100% ~ 115%)
AC Voltage
AC Regulation
Output Waveform
DC Voltage
Voltage Range
No Load Current
Power Saving Mode
12VDC
10.5~16.5VDC
1.5A@12VDC
<0.1A@12VDC
24VDC
21~33VDC
0.8A@24VDC
<0.06A@24VDC
48VDC
42~66VDC
0.5A@48VDC
<0.05A@48VDC
12VDC
10.5~16.5VDC
1.5A@12VDC
<0.1A@12VDC
24VDC
21~33VDC
0.8A@24VDC
<0.06A@24VDC
48VDC
42~66VDC
0.5A@48VDC
<0.05A@48VDC
Safety Standards
EMC Standards
E-mark
UL 458
(UL only for GFCI & Hard Wire)
FCC class A : SP-2000, SP-3000, SP-4000
FCC class B : SP-700, SP-1000, SP-1500
EN 62368-1
EN 55032 class A : SP-2000, SP-3000, SP-4000 / class B : SP-700, SP-1000, SP-1500 ;
EN 55024 EN 61000-3-2, -3-3 EN 61000-4-2, 3, 4, 5, 6, 8, 11
CISPR 25; ISO 7637-2
Eciency (Max.)
Input Under-Voltage Protection
Input Under-Voltage Recovery
Input Over-Voltage Protection
Input Over-Voltage Recovery
92%
10.5 ± 0.3VDC
12.5 ± 0.3VDC
16.5 ± 0.3VDC
14.5 ± 0.3VDC
93%
21 ± 0.5VDC
25 ± 0.5VDC
33 ± 0.5VDC
29 ± 0.5VDC
94%
42 ± 1.0VDC
50 ± 1.0VDC
66 ± 1.0VDC
58 ± 1.0VDC
----
94%
10.5 ± 0.3VDC
12.5 ± 0.3VDC
16.5 ± 0.3VDC
14.5 ± 0.3VDC
94%
21 ± 0.5VDC
25 ± 0.5VDC
33 ± 0.5VDC
29 ± 0.5VDC
95%
42 ± 1.0VDC
50 ± 1.0VDC
66 ± 1.0VDC
58 ± 1.0VDC
200 / 220 / 230 / 240 VAC (Dip Switch Selectable)
± 3%
Pure Sine Wave ( THD<3% @ Normal Load )
*WarningSP-2000/3000/4000 is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.

Summary of content (2 pages)