SP1000 Manual

15
Electrical
Specification
Model No.
Item
SP-3000-212
SP-3000-224
SP-3000-248
Input
Characteristics
Voltage
12VDC
24VDC
48VDC
Input Over-Voltage
Protection
16.5 ± 0.3VDC
33 ± 0.5VDC
66 ± 1.0VDC
Input Under-Voltage
Protection
10.5 ± 0.3VDC
21 ± 0.5VDC
42 ± 1.0VDC
Voltage Range
10.5~16.5 VDC
21~33 VDC
42~66 VDC
No Load Current
3.8A @12VDC
2.0A @24VDC
1.0A @48VDC
Power Saving Mode
<0.4A @12VDC
<0.2A @24VDC
<0.1A @48VDC
Output
Characteristics
Continuous Output
Power
3000 VA 3%)
Maximum output
Power (1Min)
> 3000 VA~3450 VA (100%~115%)
Surge Power (1Sec)
< 6000 VA
Frequency
50 / 60 Hz ± 0.5% (Dip Switch Selectable)
Output Voltage
200 / 220 / 230 / 240 VAC (± 3%)
(Dip Switch Selectable)
Efficiency max.
90%
93%
94%
Short-Circuit
Protection
1 Sec Shutdown
Output Waveform
Pure Sine Wave (THD < 3%@ Normal Load)
Signal and Control
Remote Controller
Panel Unit
CR-8 / CR-16 (optional)
LED Indicator
Red / Orange / Green LED
Dry Contact Terminal
By a relay
Remote Control
Terminal
6-port Green terminal (for inverter ON / OFF)
Protection
Input Protection
Over / Under Voltage, Reverse Polarity (Internal Fuse)
AC Output Protection
Short-Circuit, Overload
Others
Over / Under Temperature Protection
(by Heat sink Temperature +80/-20)
Environment
Operating Temp.
-20 ~40
Storage Temp.
-30 ~70
Storage Temp. &
Humidity
10 ~95% RH
Safety & EMC
Safety Standards
Certified EN 62368-1
EMC standards
Certified EN 55032 class A; EN 55024; EN 61000-3-2, -3-3
EN 61000-4-2, 3, 4, 5, 6, 8, 11
E-mark
Certified CISPR 25; ISO 7637-2
Dimension(WxHxD)
255mm X 158mm X 442mm
Weight
8.2 KG
Cooling
Temperature & Load Controlled cooling Fan
Table 10. SP-3000 for Output 200/220/230/240 VAC Specification.
Note
Voltage rangePlease refer to Figure 3
Normal load ConditionVin =12.5V/25V/50V, Vo=200/220/230/240 VAC 80% load (PF=1.0)
Operating temperaturePlease refer to Figure 4
WarningThis is a class A product. In a domestic environment this product may cause radio
interference in which case the user may be required to take adequate measures.