SP1000 Manual

34
SP-3000 ~ SP-4000 Status Definition
Description Definition
ID ID: ID Connection Error
Sof Fail Protection Sof Fail: Soft Start Fail
PLL PLL: Phase lock loop
Poff Protection Poff: Power off
OOCP Protection
OOCP: Output Over Current Protection (Over Load >
200%)
OVP Protection OVP: Over Voltage Protection
UVP Protection UVP: Under Voltage Protection
OTP Protection OTP: Over Temperature Protection
UTP Protection UTP: Under Temperature Protection
OLPH Protection OLPH: Over Load Protection High (116~200%)
OLPL Protection OLPL: Over Load Protection Low (101~115%)
Table 36. SP-3000 ~ SP-4000 Status Definition
The following data shows the function code detail setting value.
Note:
Below setting value will go back to default value by switching on / off the
inverter.
5-3-2-1. FUNC 0 : OVP setting
SETT <value> Default Model
15.0 ~ 16.5 16.5V <16.5> SP series-112 / 212
30.0 ~ 33.0 33.0V <33.0> SP series-124 / 224
60.0 ~ 66.0 66.0V <66.0> SP series-148 / 248
Table 37. OVP setting
5-3-2-2. FUNC 1 : OVP Recovery
SETT <value> Default Model
13.5 ~ 14.5 14.5V <14.5> SP series-112 / 212
27.0 ~ 29.0 29.0V <29.0> SP series-124 / 224
54.0 ~ 58.0 58.0V <58.0> SP series-148 / 248
Table 38. OVP recovery
5-3-2-3. FUNC 2 : UVP setting
SETT <value> Default Model
10.5 ~ 11.5 10.5V <10.5> SP series-112 / 212
21.0 ~ 23.0 21.0V <21.0> SP series-124 / 224
42.0 ~ 46.0 42.0V <42.0> SP series-148 / 248
Table 39. UVP setting