7-1. Troubleshooting
WARNING!
Do not open or disassemble the SR series Inverter.
Attempting to service the unit may cause risk of electrical shock or fire.
Problems and Symptoms Possible Cause Solutions
No AC Power “Output”
a. LCD Panel Display “OLP
Shutdown”
Short circuit , wiring error.
over loading.
Check AC wiring for short
circuit .
Reduce load.
b. LCD Panel Display “OVP
Shutdown”
Over input voltage (OVP) Check input voltage.
Reduce input voltage.
c. LCD Panel Display “UVP
Shutdown”
Low input voltage. (UVP) Recharge battery.
Check connections and
cables.
d. LCD Panel Display “OTP
shutdown”
Thermal shutdown. (OTP) Improve ventilation.
Make sure ventilation, grilles /
slots of the inverter are not
obstructed. Lower ambient
temperature.