Specifications Sheet
1000W Pure Sine Wave Inverters ST
FEATURES
True sine wave output (THD < 3%)
Power ON-OFF remote control
Input & output fully isolation
Load control cooling fan
Advanced microprocessor
Output frequency 50/60 Hz switch selectable
Low power saving mode to conserve energy
Built-in transfer switch and AC circuit breaker
ROF(remote override function) or ignition lockout function option
Speed up transfer time & synchronized operation with utility AC source
Input polarity reverse / under voltage / over voltage protections
Output short circuit / overload / over temperature protections
Tri-color indicators display input, output level & failure status
e-13 / CE / FCC approved
e13
OUTPUT
AC VOLTAGE
RATED POWER
SURGE POWER
WAVEFORM
FREQUENCY
AC REGULATION
STANDARD RECEPTACLES
LED INDICATOR
100/110/120VAC
1000W
2000W
True sine wave (THD < 3%)
50 / 60 Hz selectable by DIP switch
HARDWIRE
Input voltage level, output load level and fault status
ST1000-112
ST1000-124
ST1000-148
ST1000-212
220/230/240VAC
POWER FACTOR ALLOWED
COS -90q
O
~ COS +90q
O
MODEL No
.
ST1000-224
ST1000-248
A %3
NO LOAD CURRENT DRAW
0.09A
1.25A
0.65A
1.43A
0.75A
0.35A
INPUT
EFFICIENCY (Typ.)
FUSE
12VDC
24VDC
48VDC
DC VOLTAGE
12VDC
24VDC
48VDC
VOLTAGE RANGE
10.5~15.0VDC
21.0~30.0VDC
42.0~60VDC
10.5~15.0VDC
21.0~30.0VDC 42.0~60VDC
91.0%
88.0%
92.0%
90.0%
94.0%
93.0%
20A x 2
40A x4
20A x 4
REMOTE CONTROL UNIT
CR6 / CR8 optional
PROTECTION
ENVIRONMENT
SAFETY & EMC
HomPower tools and Portable equipments, Vehicle, and Yacht ...etc.
Compliance to e-13 * 72/245/EEC, 95/54/EC
44VDC
42.0VDC
OTHERS
BAT. LOW SHUTDOWN
OVER LOAD
OVER VOLTAGE
OVER TEMPERATURE
OUTPUT SHORT
BAT. POLARITY
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP. HUMIDITY
SAFETY STANDARDS
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
EMS IMMUNITY
LVD
e-MARK
DIMENSION
PACKING
COOLING
APPLICATION
10.5VDC
Shut off output voltage, re-power on to recover
15.3VDC
Shut off output voltage, recovers automatically after temperature goes down
Shut off output voltage, re-power on to recover
By fuse open
0~+40 CB
20% ~ 90% RH non-condensing
-30 C ~ +70 /BBB BC -22 F ~ +158 F / 10~95%
Meet UL458
I/P ~ O/P: 100M Ohms / 500VDC
Compliance to FCC class A
-----
-----
-----
373x236x115mm(LxWxH)
6.2kgs; 2sets / 14kgs / CARTON
30.6VDC
-----
Compliance to EN55022 class A
Compliance to EN61000-3 -2, 3
Compliance to EN60950-1
BAT. LOW ALARM
11VDC 22VDC
44VDC
11VDC 22VDC
21.0VDC 42.0VDC
10.5VDC
21.0VDC
Loading controlled cooling fan
61.2VDC
15.3VDC
30.6VDC
61.2VDC
20A x 2
40A x 4
20A x 4
CIRCUIT BREAKER
12 Amps
SYNCHRONOUS AC TRANSFER
YES
TRANSFER SWITCH
16 Amps
TRANSFER TIME
Inverter to utility AC:8~10 msec.;Utility AC to inverter:12~14 msec
STAND-BY CURRENT DRAW
0.25A
0.15A
0.38A
0.25A
0.15A
0.09A
6Amps