Datasheet

MODEL
Output
DC Voltage Range
200W Single Output with PFC Fuction
UP-200
Features :
Universal AC input active PFC
Protections: Short circuit / Over load / Over voltage / Over Temp.
Power OK signal
series
High operation temperature up to 70 C°
High power density 4.7w/in
3
UP-200-12
Rated Current
Current Range
Ripple & Noise (max.)
Voltage Adj. Range
Voltage Tolerance
Line Regulation
Load Regulation
Setup, Rise Time
Hold Up Time (Typ.)
12V
16.7A
0 ~ 16.7A
120 mVp-p
10.8 ~ 13.2V
±2%
±1%
±2%
<800ms, <40ms at full load
>16ms / 115VAC, >32ms / 230Vac at full load
Input
Voltage Range
Frequency Range
Efficiency (Typ.)
AC Current (Typ.)
Inrush Current (Typ.)
Leakage Current
90 ~ 264VAC 127 ~ 370VDC
47 ~63Hz
87%
2.4 A / 115VAC 1.2A / 230VAC (90Vac 2.88A)
25A / 115VAC 50A / 230VAC
< 2mA / 230VAC
Protection
Over Load
Over Voltage
> 105% rated output power
115% ~ 150% rated output voltage Protection type : latch-off mode
Envi onmentr
Working Temp.
Working Humidity
Storage Temp., Humidity
Temp.Coefficient
Vibration
-20°C ~ +70°C (Refer to output load de-rating curve)
20 ~ 90% RH non-condensing
-40 ~ +85°C 10 ~95% R.H
±0.03%/°C (0 ~ 50°C)
10 ~ 500Hz, 2G 10min./1 cycle, period for 60 min. Each along X,Y,Z axes
Safety & EMC
Safety Standards
EMI Conduction & Radiation
Isolation Resistance
EMS Immunity
Harmonic Current
Withstand Voltage
I/P - O/P : 4242 DC I/P - FG : 2121 DC 1 minute
EN55022 : 2006 Class B
I/P-O/P,I/P-FG,O/P-FG:100M /500VDCΩ
EN61204-3: 2000, EN55024:1998+A1: 2001+A2: 2003 light industry level, criteria A
EN61000-3-2: 2006 Class A, EN61000-3-3: 1995+A1: 2001+A2: 2005
Others
Colling
Packing
0.7kg ; 16Pcs/12.5kg
Note.2
Note.3
Note.4
Power OK signal
Dimension (W*H*D)(mm)
202x101.5x38
Free Air convection
Note.5
All using 105°C long life electrolytic capacitors
Over Temperature
90°C ±5°C
U-bracket low profile: 38mm
Free air convection for 200W
Withstand 2G vibration test
3 years warranty
High efficiency, long life and high reliability
Rated Power
200.4W
UP-200-15
15V
13.4A
0 ~ 13.4A
150 mVp-p
13.5 ~ 16.5V
±2%
±1%
±2%
201W
UP-200-24
24V
8.4A
0 ~ 8.7A
180 mVp-p
21.6 ~ 26.4V
±2%
±1%
±2%
201.6W
UP-200-48
48V
4.2A
0 ~ 4.2A
150 mVp-p
43.2 ~ 52.8V
±2%
±1%
±2%
200W
87% 88% 88%
Connection
I/P 5P / 3.96mm pitch, O/P : 4P/9.5mm terminal block with cover or 6Px2 3.96mm pitch(select by user)
Relay contact 1A / 120Vac - 230Vac
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47 uf parallel
capacitor.
3. Tolerance: includes set up tolerance, line regulation and load regulation.
4. De-rating may be needed under low input voltages. Please check the de-rating curve for more details.
5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be
re-confirmed that it still meets EMC directives.
Power Factor(Typ.)
>0.92 / 230VAC, >0.95 / 115Vac at full load
Protection type : constant current limiting, automatically after fault condiction is removed
Note
MTBF (MIL-HDBK-217F)
UL 60950-1, 2 Edition, TUV EN60950-1 : 2006+A11 Approved
nd
REV. C0
10/09/10
1