Datasheet

MODEL
Output
DC Voltage Range
350W Single Output with PFC Fuction
UP-350
Features :
Universal AC input active PFC
Protections: Short circuit / Over load / Over voltage / Over Temp.
Power OK signal
series
High operation temperature up to 65°C
3
High power density 6.4w/in
Remoter Voltage sense
2 modes Remoter ON/OFF Ctrl. Setup by user
UP-350-12
Rated Current
Current Range (convection)
Rated Power (10.5CFM FAN)
Ripple & Noise (max.)
Voltage Adj. Range
Voltage Tolerance
Line Regulation
Load Regulation
Setup, Rise Time
Hold Up Time (Typ.)
12V
29.2A
0 ~ 25A
0 ~ 29.2A
150 mVp-p
10.8 ~ 13.2V
±2%
±1%
±2%
550ms, 30ms at full load
16ms / 230VAC at full load
Input
Voltage Range
Frequency Range
Efficiency (Typ.)
AC Current (Typ.)
Inrush Current (Typ.)
Leakage Current
90 ~ 264VAC 127 ~ 370VDC
47 ~63Hz
88%
4 A / 115VAC 2A / 230VAC
22A / 115VAC 44A / 230VAC
< 2mA / 230VAC
Protection
Over Load
Over Voltage
> 105% rated output power
then 50% rating DC voltage range after 500ms the unit will shutdown
Protection type : constant current limiting, output voltage less
115% ~ 150% rated output voltage Protection type : latch-off mode
Envi onmentr
Working Temp.
Working Humidity
Storage Temp., Humidity
Temp.Coefficient
Vibration
-20°C ~ +65°C (Refer to output load de-rating curve)
20 ~ 90% RH non-condensing
-40 ~ +85°C 10 ~95% R.H
±0.03%/°C (0 ~ 50°C)
10 ~ 500Hz, 2G 10min./1 cycle, period for 60 min. Each along X,Y,Z axes
Safety & EMC
Safety Standards
EMI Conduction & Radiation
Isolation Resistance
EMS Immunity
Harmonic Current
Withstand Voltage
I/P - O/P : 4242 DC I/P - FG : 2121 DC 1 minute
I/P - O/P, I/P - FG, O/P - FG: 100M / 500VDC
Others
Cooling
Packing
1.06kg ; 16Pcs/18kg
Note.2
Note.3
Note.4
Power OK signal
ON/OFF Remote Control
2 modes setup remote ON/OFF see Function Description of J2
Dimension (W*H*D)(mm)
231x101.5x38
Free Air convection for 300W, With10.5CFM Fan for 350W
Note.5
Active AC surge current limiting
All using 105°C long life electrolytic capacitors
Over Temperature
U-bracket low profile: 38mm
Free air convection for 300W and 350W with 10.5CFM forced air
Withstand 2G vibration test
3 years warranty
High efficiency, long life and high reliability
Rated Power (convection)
Rated Power (10.5CFM FAN)
300W
350.4W
UP-350-15
15V
23.4A
0 ~ 20A
0 ~ 23.4A
150 mVp-p
13.5 ~ 16.5V
±2%
±1%
±2%
300W
351W
UP-350-24
24V
14.6A
0 ~ 12.5A
0 ~ 14.6A
150 mVp-p
21.6 ~ 26.4V
±2%
±1%
±2%
300W
350.4W
UP-350-48
48V
7.3A
0 ~ 6.25A
0 ~ 7.3A
150 mVp-p
43.2 ~ 52.8V
±2%
±1%
±2%
300W
350.4W
89% 89% 90%
Connection
I/P 5P / 3.96mm pitch, O/P : 6P/9.5mm terminal block with cover or 9Px2 3.96mm pitch(select by user)
Open Darin
Remote Voltage sense
Compensates for wire voltage drop
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47 uf parallel
capacitor.
3. Tolerance: includes set up tolerance, line regulation and load regulation.
4. De-rating may be needed under low input voltages. Please check the de-rating curve for more details.
5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be
re-confirmed that it still meets EMC directives.
Note
MTBF (MIL-HDBK-217F)
DC fan supply is provided
UL 60950-1, 2 Edition, TUV EN60950-1 : 2006+A11 Approved
nd
EN55022: 2006 Class B
EN61204-3: 2000, EN55024:1998+A1: 2001+A2: 2003 light industry level, criteria A
EN61000-3-2: 2006 Class A, EN61000-3-3: 1995+A1: 2001+A2: 2005
REV. C4
11/05/26
100°C ±5°C With N2, 90°C ±5°C With TH1 sense near D26 heat sink
100°C ±5
100°C ±5°C With TH1
sense near D26 heat
sink
°C With N2,
,re-power on to recover
1
58.13K Hours