Based on standard RI-02 models
ORDERING INFORMATION
RI-02SMD - 10-15
AT Ranges**
Series
**Customer specic AT ranges are possible. Please contact your
local sales representative.
Coils
All characteristics are measured using the Philips Standard
Coil. For denitions of the Philips Standard Coil, refer to
“Application Notes” in the Reed Switch Technical & Applica-
tion Information Section of this catalog.
Life expectancy and reliability
e life expectancy data given below are valid for a coil
energized at 1.25 times the published maximum operate
value for each type in the RI-02 series.
No load conditions (operating frequency:
100Hz)
Life expectancy: min. 10
8
operations with a failure rate of
less than 2 x 10
-10
with a condence level of 90%.
End of life criteria:
Contact resistance > 1Ω after 2 ms
Release time > 2 ms (latching or contact sticking).
Loaded conditions (resistive load: 5 V; 100 mA;
operating frequency: 125 Hz)
Life expectancy: min. 2 x 10
6
operations with a failure rate
of less than 10
-8
with a condence level of 90%.
End of life criteria:
Contact resistance > 1Ω after 2.5 ms
Release time > 1 ms (latching or contact sticking).
Loaded conditions (resistive load: 20 V;
500 mA; operating frequency: 125 Hz)
Life expectancy: min. 2 x 10
6
operations with a failure rate
of less than 10
-7
with a condence level of 90%.
End of life criteria:
Contact resistance > 2Ω after 2.5 ms
Release time > 2.5 ms (latching or contact sticking).
Switching dierent loads involves dierent life expectancy
and reliability data. Further information is available on
request.
Mechanical Data
Contact arrangement is normally open; lead nish is
tinned; net mass is approximately 90mg; and can be
mounted in any position.
Shock
e switches are tested in accordance with “IEC 68-2-27”,
test Ea (peak acceleration 100 G; half sinewave; duration
11ms). Such a shock will not cause an open switch (no
magnetic eld present) to close, nor a switch kept closed
by an 80 AT coil to open.
Vibration
e switches are tested in accordance with “IEC 68-2-26”,
test Fc (acceleration 10G; below cross-over-frequency 57
to 62 Hz; amplitude 0.75 mm; frequency range 10 to
2000 Hz; duration 90 minutes.) Such a vibration will not
cause an open switch ( no magnetic eld present) to close,
nor a switch kept closed by an 80 AT coil to open.
Mechanical Strength
e robustness of the terminations is tested in accordance
with “IEC 68-2-21”, test Ua1 (load 10 N).
Operating and Storage Temperature
Operating ambient temperature; min: -55°C; max:
+125°C. Storage temperature; min: -55°; max: +125°C.
Note: Temperature excursions up to 150°C may be
permissible. For more information contact your nearest
Comus Group sales oce.
Soldering
e switch can withstand soldering heat in accordance
with “IEC 68-2-20”, test Tb, method 1B: solder bath at
350 ± 10°C for 3.5 ± 0.5 s. Solderability is tested in ac-
cordance with “IEC 68-2-20” test Ta, method 3: solder
globule temperature 235°C; ageing 1b: 4 hours steam.
Through-hole Reed Switches
e attachment method is typically eutectic soldering.
RoHS requires solder with no elemental lead (Pb). SAC
alloy (96,5Sn / 3AG / 0,5Cu) is the most popular choice.
Reed switches can be soldered by hand or by wave sol-
der processing. Comus Technology recommends the
maximum wave solder temperature (measured at the reed
switch leads) as 270°C for 10 seconds. Temperature and
time in excess of the recommended levels may result in
damage to the reed switch. All of our through-hole reed
switches will be compatible with either SAC alloy or
eutectic soldering process.