RI-90 Series Dry Reed Switch
Technical Specications
Parameters Test Conditions Units RI-90
Operating Characteristics
Operate Range AT 15-40
Release Range AT 5 (min)
Operate Time - including Bounce (typ.) ms 1.0
Bounce Time (typ.) ms 1.5
Release Time (max)
ms
1.0
Resonant Frequency (typ.) Hz TBD
Electrical Characteristics
Switched Power (max) W 5
Switched Voltage DC (max) V 175
Switched Voltage AC, RMS value (max) V 125
Switched Current DC (max) mA 400
Switched Current AC, RMS value (max) mA 280
Carry Current DC (max) A 0.5
Breakdown Voltage (min) V 200
Contact Resistance (initial max.) 140
Contact Resistance (initial typ.) 120
Contact Capacitance (max) without test coil pF 0.8
Insulation Resistance (min) RH ≤ 45% 10
3
Mounting
e leads should not be bent closer than 1 mm to the
glass-to-metal seals. Stress on the seals should be avoided
Care must be taken to prevent stray magnetic elds from
inuencing the operating and measuring conditions.
As part of the company policy of continued product improvement, specications
may change without notice. Our sales ofce will be pleased to help you with the
latest information on this product range and the details of our full design and
manufacturing service. All products are supplied to our standard conditions of
sale unless otherwise agreed in writing.
USA Tel: +(1)973 777 6900 / Fax: +(1) 973 777 8405 Belgium Tel: + 32 (0)12 390400
Page 2 of 3