Installation Manual

Lumi n S ma r t Pan el - Ou tdo or
DOCUMENTATION AND INSTALLATION MANUAL
17
STEP 10. Connect LSP Power Circuit and Label Breaker
WARNING: HIGH VOLTAGE. ENSURE MAIN BREAKER IS OFF. MAIN SERVICE LINES ARE ALWAYS LIVE.
AVERTISSEMENT: HAUTE TENSION. ASSUREZ-VOUS QUE LE DISJONCTEUR PRINCIPAL EST ÉTEINT. LES
CONDUCTEURS DE SERVICE PRINCIPAUX SONT TOUJOURS SOUS TENSION.
Tools: Screwdriver, pliers, and wire stripper
NOTE: Connect the LSP wires as pictured to the existing neutral bar and a double-pole 15- to 20-amp
breaker, landing Line A on an A-row breaker terminal and Line B on a B-row breaker terminal.
Exception: Use a single-pole breaker for “Line A” and securely cap “Line B” in panels with two-wire
single-phase power rather than three-wire single-phase (split phase). Mark the breaker with a clearly
identifying label (ex. “Lumin Smart Panel Power”). DO NOT CONNECT THESE CONDUCTORS TO GFCI
BREAKERS. Do not double-tap breakers unless they are appropriately rated.
A
B
A
B
A
B
Neutral
(White)
Line A (Black)
to A-Row Breaker
Line B (Red)
to B-Row Breaker