User's Manual

ELECTRICAL SPECIFICATIONS
:
Frequency Range : See Table 1
Pass band Gain @ min attenuation : 60 dB minimum
Manual Gain Control Range : 15 dB minimum
(continuous)
Pass band Ripple : ±1.5 dB typical
Noise Figure @+25
°C at max gain : 5.0 dB max
3rd Order Intercept point
Uplink : +45 dBm typical
Downlink : +45 dBm typical
Output Power @ 1dB Compression
Uplink : +32 dBm (typ)
Downlink : +32 dBm (typ)
Isolation between Up/Down Link : 80 dB min
Input/ Output Impedance : 50 Ohms
VSWR (Input/Output) : 1.5: 1 max
Power Supply : 110VAC/0.67Amp
: 240VAC/0.34 Amp
: 50 to 60 Hz
Page 5